HT-SB60 (serv.man7). Improve sound stability at low volume level - Sharp Audio Technical Bulletin (repair manual). Page 4

Read Sharp HT-SB60 (serv.man7) Technical Bulletin online

AUD 2013 04 08 
 
Date of Issue:        29
th
 April 2013      
         
Classification: 
White 
AUDIO TECHNICAL BULLETIN
 
Page 4 of 6 
 
 
Sharp Electronics (UK) Limited 
Reference 
– TSI-1330003
 
Revision  - 2 
 
White 
– Carry out as required 
Yellow 
– Carry out as required and whenever the unit comes in for service 
 Red 
– Carry out on all units   
Flash Writer Connection 
The connection between Flash Writer and Main Unit is shown as below. 
 
 
 
Flash Programming 
 
1.  Insert the FFC cable into the flash terminal at the bottom cabinet of the Main Unit (HT-SB60). 
2.  Plug the AC cord into an AC supply. The HT-SB60 LED lights up and the Flash writer 
POWER, PASS & ID ERR indicators will light up. 
3.  Press the START button on the jig to start programming. 
4.  The PASS indicator will flashing during programming 
5.  The PASS indicator will permanently light up once programming is completed. 
6.  Remove the AC cord from the AC supply. 
7.  Remove the FFC cable from the Main Unit. 
 
Confirmation of Updated Software Version 
 
1.  Plug the AC cord into the AC supply while holding down the "STANDBY" and "INPUT" 
buttons on the main unit. 
2.  The Display appears as - 
SB60 1026
 
3.  Press the STANDBY button again to return back to normal operation. 