HT-SB60 (serv.man7). Improve sound stability at low volume level - Sharp Audio Technical Bulletin (repair manual). Page 3

Read Sharp HT-SB60 (serv.man7) Technical Bulletin online

AUD 2013 04 08 
 
Date of Issue:        29
th
 April 2013      
         
Classification: 
White 
AUDIO TECHNICAL BULLETIN
 
Page 3 of 6 
 
 
Sharp Electronics (UK) Limited 
Reference 
– TSI-1330003
 
Revision  - 2 
 
White 
– Carry out as required 
Yellow 
– Carry out as required and whenever the unit comes in for service 
 Red 
– Carry out on all units   
Loading the firmware to the Flash Writer 
 
1.  Download the software for the S550-SFW1U serial flash microcomputer programmer. 
2.  Extract the file and fol
low the instructions provided in the file “readme.txt”. 
3.  Once the serial flash programmer is installed, connect the programmer to a PC using a USB 
cable. 
4.  Open the S550-SFW1U application. 
5.  Within the S550-SFW1U application, use the settings as per the below picture. 
 
 
 
6.  Load the file SB60_1026_121127.mot. 
7. 
Select “Download” and the jig will have the latest firmware installed. 
8.  Exit the S550-SFW1U application and remove the jig from your PC. 
 
The jig is now programmed and ready to use. 
Note 
– The jig only needs programming once. 
Page of 6