PT-MZ16K, PT-MZ13K, PT-MZ10K (serv.man2) - Panasonic Projector Service Manual (repair manual). Page 23

Read Panasonic PT-MZ16K / PT-MZ13K / PT-MZ10K (serv.man2) Service Manual online

INF-13
SECTION 1 SERVICE INFORMATION
<MZ16K/MZ13K/MZ10K>
2. CMS
  • Setting of the Color Management (Color space converter) System operation.
  - ON : Enable the Color Management system function. (Default setting)
  - OFF : Disable the Color Management system function.
3. SELF CHECK
  • Self-diagnosing information Displays.
① – Model name
② – Serial no.
------------------- VERSION-----------------------------
③ – Main CPU firmware 
④ – Sub CPU firmware 
⑤ – FPGA (FPGA1/FPGA2/FPGA)
⑥ – CPLD firmware 
⑦ – DIGITAL LINK firmware 
⑧ – LD driver (LD1/LD2) firmware 
⑨ – Power CPU firmware
⑩ –  Emulate setting 
------------------- DEVICE CHECK-----------------------------
⑪ – Intake air temperature (Celsius/Fahrenheit)
⑫ – Exhaust air temperature (Celsius/Fahrenheit)
⑬ –  Airflow sensor check (Sensor detected vale/
AD conver-
sion value/Correction value)
⑭ – LD1 temperature (Celsius)
⑮ – LD2 temperature (Celsius) 
⑯ – Power temperature (NORMAL
/HIGH)
⑰ – 
 
LD1 check (1: On / 0 :Off)
⑱ – 
 
LD2 check (1: On/0:Off)
⑲ – Fan check (1: Normal/0:Abnormal)
⑳ – R-color sensor check (Average: Red/Green/Blue)
㉑ – B-color sensor check (Average: Red/Green/Blue)
㉒ – Pressure sensor check (hPa/Celsius)
㉓ – Angle sensor check (Horizontal/Vertical)
[Note]
  •   Items 
 to ㉓ indicates the status of "NG" or "OK". If the "NG" indicates in red, the projector has an abnormality now. If the 
"OK" indicates in red, the projector had an abnormality in the past and operates normally now. 
The item [DEVICE CHECK] indicates "OK" in white when the all the items ⑪ to ㉓ are OK. If one of the itmes ⑪ to ㉓ has 
an error, it indicates [NG] in red. If one of the itmes ⑪ to ㉓ had an error in the past, it indicates "OK" in white. 
   •  To clear the error status, press the [MENU] key in the SELF CHECK mode, the confirmation window will appear and select 
[OK] to clear.
  • This must be done after finishing the repair or maintenance.
SELF CHECK
1/3
MODEL        : PT-MZ16K
SERIAL NO.   : AB12345678
---------- VERSION --------------
MAIN         : 1.00.00
SUB          : 1.00.00
FPGA         : 01.01/02.02/03.03
CPLD         : 01.01
DIGITAL LINK : 1.30.90.c
LD           : 1.160.0/5.47.06
POWER        : 1.00
EMULATE      : DEFAULT
DEVICE CHECK : OK






SELF CHECK
2/3
---------- DEVICE CHECK ----------
CHANGE
OK : AIR TEMP 025/000
OK : OUT TEMP 025/000
OK : AIR FLOW 025.0/000/000.0
OK : LD1 TEMP 025
OK : LD2 TEMP 025
OK : POWER TEMP NORMAL
OK : LD1 1 1
OK : LD2 1
NG
 : FAN 111
0
 1111 111
OK : PHOTO R       0.0/    0.0/    0.0
OK : PHOTO B       0.0/    0.0/    0.0
DEVICE CHECK : 
NG








SELF CHECK
3/3
CHANGE
OK : ATM 1013.0/25.0
OK : ANGLE H +0.00/V +0.00
DEVICE CHECK : 
NG
 CLEAR ERROR INFOMATION?
OK
CANCEL
Page of 116
Display

Click on the first or last page to see other PT-MZ16K / PT-MZ13K / PT-MZ10K (serv.man2) service manuals if exist.