INF-16
SECTION 1 SERVICE INFORMATION
<MZ16K/MZ13K/MZ10K>
14. INDICATOR SETTING
  • Set this when you want to turn off the indicator LED.
  – INDICATOR MODE
    – NORMAL : The indicator maintains lighting (Default)
    – OFF : The indicator will be forcibly turned off.
    – TIMEOUT : The indicator turns off when no operation is taken for a certain time.
  – NO ACTIVITY TIME
    Setup the time to turn off when INDICATOR MODE setting is TIMEOUT.
    You can set  the time up to 15 minutes in 1 minute. (Default  15 MIN)
    *If INDICATOR MODE setting is NORMAL or OFF, this will be grayed out.
15. COMMAND CONTROL TIMEOUT
• Setting up the communication specifications of the command control.
  - 0 SEC : 1 command 1 session mode. (Default)
  - 30 SEC : Keeps a session for 30 seconds.
  - Switches the time with qw button.
16. DIGITAL LINK OPTION
  • Setting up if the DIGITAL LINK firmware update failed.
  - 0: Normal mode (Default)
  - 1: Writing mode by the special tool
17. HDMI HOT PLUG CONTROL
  •  At the turning on the projector, setup when the abnormal HDMI signal (no information frame, etc.) is output from source 
equipment, it controls the Hot Plug and outputs the signal again.
    - DISABLE : Hot Plug is "High" during connecting to the source equipment.*1 
    - POWER ON : Hot Plug is switched from "Low" to "High" once when starting up the main power supply. (Default) *1, *2
    *1 :  When changing the setting of "EDID Selection" or "EDID Mode" on the HDMI IN menu, the Hop Plug becomes 
"Low".
    *2 : The source equipment may output the signal again to the connected equipment (monitors, projectors).
18. WAVE PLACE CONTROL
  •  Setting up the color correction function with the wave plate turning operation. 
- OFF: Disable the correction function. 
- ON: Enable the correction function (Default)
19. LIGHT OUT CONTROL
  •  Setting up the operation if the dynamic contrast is set off. 
- OFF: Native contrast, measurement mode. 
- ON: Normal mode (Default)