Error response
“ERR1”
 Command format error
“ERR2”
 Out of parameter
“ERR3”
 Busy or unavailable time
“ERR4”
 Timeout or unavailable time
“ERR5”
 Data length error
“ERRA”
 Invalid password
Example. Asking command on power condition "QPW"
1. Connection to projector
IP = 192.168.0.8      port = 1024
2. Response received
Response = "NTCONTROL 1 1aa6c14e" + (CR)
1aa6c14e = 8 byte random value
3. Hash data is created from "admin1 : panasonic : 1aa6c14e" by MD5 algorizm
admin1 = Administrator user name
panasonic = "admin1" password
Hash value = "01466bc27ed8c0b7e607471580c55953"
4. Data transmission
Transmitting data = "01466bc27ed8c0b7e607471580c5595300QPW" + (CR)
5. Receiving response
Receiving data = "00000" + (CR)
6. Close the communication with projector
Error massage
Terminater
4 bytes
 1 byte
 (CR)  0x0d
 (CR)  0x0d
 (CR)  0x0d
 (CR)  0x0d
 (CR)  0x0d
 (CR)  0x0d
INF - 12
    4. 2. 3. WEB Control Admin without password setting (Non protect mode)
      4. 2. 3. 1. Connecting procedure
1. Get the projector IP address and port number (default is 1024) and request the connection to the projector.
  IP address and the port number can be get in menu of projector.
Get it in Main menu, "Network" -> "Network Status"
Get it in Main menu "Network" -> "Network Control" -> "Command Port"
2. Receive the response from projector
Responding data
Mode: 0 = Non protect mode
      4. 2. 3. 2. Command transmission
Send the command with the style below.
Transmission data
Receiving data
Mode
“NTCONTROL”
‘   ’
‘0’
IP Address:
Port number:
Data
Space
Terminater
(CR)
0x0d
1 byte
(ASCII character)
0x20
0x30
9 bytes
1 byte
1 byte
Header
Data
Terminater
‘0’
‘0’
Control command
(CR)
(CR)
1 byte
1 byte
Non defined length
1 byte
0x30
0x30
(ASCII charactor)
0x0d
0x30
0x30
(ASCII charactor)
0x0d
Header
Data
Terminater
‘0’
‘0’
Control command
1 byte
1 byte
Non defined length
1 byte
INF - 12