  4. 2. Control through LAN terminal
    4. 2. 1. Connection example
    4. 2. 2. WEB Control Admin for password set (Protect mode)
      4. 2. 2. 1. Connecting procedure
1. Get the IP address and port number (default is 1024) of the projector and request the connection to the projector.
  IP address and the port number can be get in menu of projector.
Get it in Main menu, "Network" -> "Network Status"
Get it in Main menu "Network" -> "Network Control" -> "Command Port"
2 R
i
th
f
j t
IP Address:
Port number:
It is possible to control this projector by connecting PC to the LAN termainal on the side of this projector.
Connection and command transmission changes depending on Mode ( Admin Password is set or not with WEB
CONTROL).
When setting the password (protect mode), please follow 4.2.2. When not setting the password (non protect mode),
please follow 4.2.3.
The control command is common with SERIAL terminal command, so please refere to "Control command chart".
<Terminals on the side>
LAN terminal
PC for control
LAN cable
(Streight)
Note:
Lan cable and Hub are not standard accessories. Please purchase locally.
When connected directly, streight type cable is recommended.
LAN cable
(Streight)
Hub
INF - 11
2. Receive the response from projector.
Response data
Mode: 1 = Protect mode
3. 32bytes hash value is created using the data below by MD5 algorizm.
xxxxxx:yyyyy:zzzzzzzz″
xxxxxx : Administrator user name of WEB CONTROL (Default is "admin1")
yyyyy
Password of admin1 above (Default is "panasonic")
zzzzzzzz: Random value of 8 bytes got from response data
:  colon
: Separator
      4. 2. 2. 2. Command transmission
Send with the command style below.
Transmitting data
Receiving data
1 byte
1 byte
Random numbers
Terminater
Data
Space
Mode
Space
0x0d
8 bytes
1 byte
“NTCONTROL”
‘   ’
‘1’
‘   ’
“zzzzzzzz”
(CR)
(ASCII character)
1 byte
1 byte
Non defined length
1 byte
0x31
0x20
(ASCII code hexadecimal)
0x20
9 bytes
1 byte
Terminater
‘0’
(CR)
Data
Control command
0x30
0x30
0x30
(ASCII charactor)
‘0’
‘0’
Control command
0x0d
Header
(CR)
Data
Terminater
0x0d
1 byte
1 byte
(ASCII charactor)
Non defined length
Hash value
32 bytes
(Refer to item3 in 4.2.2.1.)
Header
‘0’
0x30
1 byte
INF - 11
Page of 71