Read Panasonic KV-S3105C / KV-S3085 (serv.man3) Service Manual online
Note:
1. Procedure for monitoring (for Front)
a. Turn off the scanner.
b. Remove the Right Front Panel and Board Box Cover. (See 8.4.2.)
c.
Turn both Reference Plates (Front and Back) to the white side.
d. Prepare to monitor a Test pin (TPFRO, TPFRE, TPFGO, TPFGE, TPFBO, or TPFBE).
→ Oscilloscope input mode: AC IN
e. Restart the scanner while pushing “SCAN” and “OTHERS” keys.
f.
After setting input value to “14” on “CCD test (F. Lamp), execute CCD Test (F. Lamp), according to 9.6.2.2.
g. Confirm the waveform. (See Fig 10.2-1.)
2. Procedure for monitoring (for Back)
a. Turn off the scanner.
b. Remove the Right Front Panel and Board Box Cover. (See 8.4.2.)
c.
Turn both Reference Plates (Front and Back) to the white side.
d. Prepare to monitor a Test pin (TPBRO, TPBRE, TPBGO, TPBGE, TPBBO, or TPBBE).
→ Oscilloscope input mode: AC IN
e. Restart the scanner while pushing “SCAN” and “OTHERS” keys.
f.
After setting input value to “14” on “CCD test (B. Lamp), execute CCD Test (B. Lamp), according to 9.6.2.2.
g. Confirm the waveform. (See Fig 10.2-1.)
Fig. 10.2-1
117
KV-S3105CSERIES / KV-S3085SERIES