SR-PE55LTQ - Panasonic Home Appliance Service Manual (repair manual). Page 13

Read Panasonic SR-PE55LTQ Service Manual online

13
6.6 Confi rmation Methods for Inner-Pot Detector Operation
The micro switch is a safety switch for detecting whether the inner pot is put in, of which the mechanism is that, by 
means of the mechanical up–and-down movement of the bottom sensor, a safety rod is used for switching on or off 
the microswitch.
● Confi rmation methods 
  Is it in the following relationships?
LCD state
State of the warm-keeping LED 
indicator light (orange)
When the inner pot is put in
The indicator light is lit
When taking out the inner pot in 
warm keeping
 Flashing
Around 5s after taking out the inner 
pot, the buzzer sounds once, and 
then the indicator light turns off.
•  If the safety rod is not in the relationship shown as below, check its movement.
•  If the safety rod moves normally, please replace the safety microswitch.
6.7  Adjustment methods for holding 
temperature
The holding temperature can be adjusted by rotating 
VR1 on the control panel (operation component).
Please rotate VR1 at the side of LCD with a screwdriver.
The temperature will rise by 1℃ if rotating VR1 
clockwise for 10°.
Since the temperature will change accordingly in all 
steps, please do not adjust the temperature with an 
increment of 3℃ or more. 
(Note)
Disconnect the power in temperature adjustment.
Control Unit A 
(operation component)
IP4749_SR_PE45_PE55_Eng_07_140314.indd   13
IP4749_SR_PE45_PE55_Eng_07_140314.indd   13
2014-3-14   9:12:39
2014-3-14   9:12:39
Page of 29