SR-PE55LTQ - Panasonic Home Appliance Service Manual (repair manual). Page 14

Read Panasonic SR-PE55LTQ Service Manual online

14
7.  Disassembly and Assembly Instructions
7.1 Before 
Disassembly
7.1.1 Maintenance 
attentions
 
Please observe the attentions.
The matters requiring special attention in the course of maintenance must be indicated on the labels 
and seal strips of housing, bottom frame and component, etc. Please observe these attentions as 
seriously as observing the operation manual.
Electric 
shock 
hazard
 
Electric shock
 Since the control panel carries AC 220V, you may suffer electric shock if touching any live component 
of it. Thus, please wear insulating gloves in power-on maintenance or while removing the dangerous 
component to be replaced to avoid electric shock.
As some components in the inverse circuit carry high voltage, please take care in power-on operation.
 
Please use original components for maintenance.
Components of this appliance feature flame retardance, voltage withstanding and other safety 
characteristics, thus please use components with the same characteristics for replacement. Especially 
for the critical security components with the mark of “ 
 ” indicated in the circuit diagram and the 
component list, please use original components.
 
If required, please install and wire the components as before.
For safety, this product is provided with some insulating materials such as hose and adhesive tape; 
besides, some components fi xed on the upper part of the printed circuit board. When using ties to 
secure the internal wiring, do keep them away from heating or high-voltage components. The wiring 
must be placed well as before. 
The replaced lead shall be kept away from the sharp edges of component.
 
After maintenance, please conduct safety inspection.
Please inspect whether all the usable screws, components and leads dismantled have been put 
back to the original places correctly and whether there are any components whose performance has 
degraded near the maintenance area.
 Insulation resistance
As required, the insulation resistance between plug-in electric terminal and exposed 
area shall be 1MΩ or above.
 
Without permission, do not modify the appliance, components and elements in maintenance period.
 
When a wiring unit is provided as maintenance component, even if it breaks partially, please replace 
the whole wiring unit, rather than re-connect it.
 
Warning
IP4749_SR_PE45_PE55_Eng_07_140314.indd   14
IP4749_SR_PE45_PE55_Eng_07_140314.indd   14
2014-3-14   9:12:39
2014-3-14   9:12:39
Page of 29
Display