3.4.7.
Hot water cannot be poured out, hard to pour out. (Air pump method)
3.5.
Operating and LCD monitor display example
< Status of each lamp when boiling cool water. >
1. During the boiling operation of ordinary water, the 208F/98C LED will be blink and Long boil/Reboil will be lighted. After detec-
tion of boiling, the 208F/98C LED changes to continuous lighting and Long boil/Reboil LED will be extinguishes.
2. When pure ordinary water in and set 140F/60C keep warm by pressing the “Select” pad, the 140F/60C LED will be blink and
Long boil/Reboil will be lighted. After detection of boiling, the 140F/60C LED changes to continuous lighting and Long boil/
Reboil LED will be extinguishes.
< Status of each lamp when the 208F/98C keep warm is switched to the 140F/60C keep warm by pressing the “Select” pad. 
>
1. When the 140F/60C keep warm is set by pressing the “Select” pad, 140F/60C will be blink. When the water temperature
reaches 140°F or 60°C changes to continuous lighting.
< Status of each lamp when setting the Long boil. >
1. To set the Long boil for cool water, press the “Long boil/Reboil” pad once. Then both the 208F/98C LED and the Long boil/
Reboil LED start blink.
2. To set the Long boil during either the 208F/98C keep warm or 140F/60C keep warm by press “Long boil/Reboil” pad twice.
Then both the 208F/98C LED and Long boil/Reboil LED start blink. Upon completion of the Long boil, the Long bol/Reboil
LED extinguishes and the 208F/98C changes to continuous lighting (if set Long boil during 208F/98C keep warm). Or then
both the 140F/60C LED and Longboil/Reboil LED start blink. Upon completion of the Long boil, the Long boil/Reboil LED
extinguishes and the 140F/60C changes to continuous lighting.(if set Long boil during 140F/60C keep warm).
< Status of each lamp when setting cleaning mode. >
1. To set cleaning mode by pressing “Select” 3 seconds, then both 208F/98C LED and Long boil/Reboil LED start lighted. Upon
completion of the cleaning, the 208F/98C LED changes to blink and Long boil/Reboil LED extinguishes. When the water tem-
perature reaches 208°F or 90°C, the 208F/98C changes to continuous lighting.
Check
Diagnostics Method
Action
Rubber packing set
Is Packing A, Seal Packing B, Lid Comp. broken?
Replace broken part.
Pump comp.
Does Supporting plate pad rebound after pushing?