2.25. Valve A, Seal ring, spring B assembly
  1. Assemble Seal ring on Valve A, then assemble Spring B.
  2. Set 4 legs of Valve A of Pump comp. as picture below.
Operating point
  Flat side of Sealing should reach to base of Valve A.
Fig. 26
Valve A
Seal ring
Spring B
Leg
Hole
• Picture when remove Spring B. to make 
more understand how to set Valve A
2.26. How to Check Pump comp.
    Use finger to block 1 position, and push tightly to prevent air leak from Lid. (If there is some rebound on Pump 
comp., it means O.K.)
Operating point
  -  If do not set Packing lid well it may not withstand pushing reaction (Packing lid should not be open).
  -   Assemble Pump comp. to Lid after check air leak.
Fig. 27
Lid packing
Valve A
Push