5.5.
Failure diagnostics chart
5.5.1.
No power. (No indication, No pouring)
The items in the Check correspond to those shown in Check Point (
5.4.Check Point).
5.5.2.
Water is not boiled. (Water pours out)
The items in the Check correspond to those shown in Check Point (
5.4.Check Point).
5.5.3.
Hot water cannot poured out or water flow is obstructed. (Water is boiled)
Check point
The items in the Check correspond to those shown in Check Point (
5.4.Check Point).
5.5.4.
Long Boil / Reboil LED and VIP keep warm LED are lighted up alternately.
Check point
The items in the Check correspond to those shown in Check Point (
5.4.Check Point).
5.5.5.
Select pad doesn’t work.
Check
Diagnostic Method
Action
Thermal fuse (Comp.)
Is there connection in thermal fuse? 
Replace the Thermal fuse comp.
Keep warm heater
Is there connection in keep warm heater? (Approx.452ohms)
Replace the Container comp.
Power cord
Is there connection in the power cord? (0Ω)
Replace the Power cord.
Lead wire assy. E
Is there connection in the lead wire assy. E? (0Ω)
Replace the Lead wire assy E.
When the above parts are normal
Replace the Control unit A comp.
(Operation)
Replace the Control unit B comp.
(Bottom)
Check
Diagnostic Method
Action
Boiling heater
Is there connection in boil heater? (Approx.57ohms)
Replace the Container comp.
When the above parts are normal
Replace the Control unit A comp.
(Operation)
Replace the Control unit B comp.
(Bottom)
Check
Action
Is the filter (located at the bottom of the container) clogged?
Clean up or replace the filter.
Check
Diagnostic Method
Action
Electric pump
I turn ON. And press the “Lock/Unlock” button first and then the “
“4Speed Dis-
penser” button
. Is the motor heard running?
Replace the Electric pump.
Lead wire assy. E
Is there connection in the lead wire assy. E? (0Ω)
Replace the Lead wire assy E.
When the above parts are normal
Replace the Control unit A comp.
(Operation)
Replace the Control unit B comp.
(Bottom)
Check
Action
Is there water inside?
Supply water and press
the“Long Boil / Reboil”button.
Check
Diagnostic Method
Action
Thermistor assy. comp.
Is there connection in thermistor assy? (Approx.20deg.Approx.45ohms)
Replace the Thermistor assy.
comp.
When the above parts are normal
Replace the Control unit A comp.
(Operation)
Replace the Control unit B comp.
(Bottom)
Check
Diagnostic Method
Action
-
-
Replace the Control unit B comp.
(Bottom)