NC-EG4000WTS, NC-EG3000WTS (serv.man2) - Panasonic Home Appliance Service Manual Simplified (repair manual). Page 12

Read Panasonic NC-EG4000WTS / NC-EG3000WTS (serv.man2) Service Manual Simplified online

12
2. If water wells up, and “90” LED turns on and breaks
reshuffling in warming.(warming is in a state)
3. Time required for the reboil procedure
・ From 98 keep-warm : approx. 2.5-4 min.
• From 90 keep-warm : approx. 
4-6.5 min.
・ From 80 keep-warm : approx. 6-12 min.
・ From 70 keep-warm : approx. 9-17.5 min.
(Amount of water : Maximum Room temperature : 20deg)
4. Time required to reach the settled keep warm tempera-
ture
• 90---
98 keep-warm : approx. 7-16min
・ 90---80 keep-warm : approx. 1.5-2.5hours
・ 90---70 keep-warm : approx. 7.5-11hours
(Amount of water: Maximum Room temperature: 20deg
Initial keep-warm setting: 90)
5.2.3.
Pour out test
How to operate
1. Pour water into the container. (up to white line)
2. Supply with electric power.
3. Press “Lock / Unlock” button.
4. Press “Pour Out” button. (Continuation)
Instructions
1.
“Lock / Unlock” LED turns on when it press the “Lock /
Unlock” button, and water flows from a beak when it
press the hot water supply button.
5.3.
Abnormal mode
5.3.1.
Empty  heating  /  abnormality  high
temperature mode
Shift condition
When it connects power supply cord to a container in a state
without water and turns on electricity.
• When, in the state that a container has little water (0.4L or
less), a kettle is in condition to have been started.
Instructions
• LED : Flashing (“Long  Boil  /  Reboil”LED, “98”LED)Alterna-
tion flashing of 0.2 seconds
• Heater : OFF
• Others:It does not take "Select / Cleaning(Press 3s)" button.
Return movement
When it pressed the “Long Boil / Reboil” button or when the
disconnection of the sensor restored it..
5.3.2.
Bottom sensor disconnection
Shift condition
When it detects bottom sensor disconnection.
Instructions
• LED : Flashuing (“Long Boil / Reboil” LED, "98" LED) for 0.1
seconds ON / 0.3 second OFF sequentially flasuing
• Heater : OFF
• Others : -
Return movement
When the disconnection of the sensor restored it or when a
breakdown made them return by simultaneous influence of
“Long Boil / Reboil” button and  “Select / Cleaning(Press 3s)”
button.
5.3.3.
Temperature input extraordinary 
mode
Shift condition
When boiling couldn't be detected even if 120 minutes
passed from starting.
Instructions
• LED : Flashuing (“Long Boil / Reboil” LED, "80" LED) for 0.1
seconds ON / 0.3 second OFF sequentially flasuing
• Heater : OFF
• Others : -
Return movement
• When the disconnection of the sensor restored it or when a
breakdown made them return by simultaneous influence of
“Long Boil / Reboil” button and  “Select / Cleaning(Press 3s)”
button.
Page of 26