NC-DG3000WTS (serv.man2) - Panasonic Home Appliance Service Manual Simplified (repair manual). Page 16

Read Panasonic NC-DG3000WTS (serv.man2) Service Manual Simplified online

16
5.5.6.
Lock/Unlock pad doesn’t work.
The items in the Check correspond to those shown in Check Point (
5.4.Check Point).
5.5.7.
Hot water cannot be poured out smoothly. Noise is getting big while operating and noisy. 
The Container is dirty with water stain.
5.5.8.
Hot water cannot be poured out, hard to pour out. (Air pump method).
Check
Diagnostic Method
Action
Lead wire assy. E
Is there connection in the lead wire assy. E? (0Ω)
Replace the Lead wire assy E.
When the above parts are normal
Replace the Control unit A comp.
(Operation)
Replace the Control unit B comp.
(Bottom)
Check
Diagnostic Method
Action
-
-
Wash with citric acid.
-
-
Replace the Control unit A comp.
(Operation)
Replace the Control unit B comp.
(Bottom)
Check
Diagnostic Method
Action
Rubber packing set
Is Packing A, Seal Packing B, Lid Comp. broken?
Replace broken part.
Pump comp.
Does Supporting plate pad rebound after pushing?
Replace Pump comp.
Page of 31
Display

Click on the first or last page to see other NC-DG3000WTS (serv.man2) service manuals if exist.