5.3.
Abnormal mode
5.3.1.
Empty  heating  /  abnormality  high
temperature mode
Shift condition
When it connects power supply cord to a container in a state
without water and turns on electricity.
• When, in the state that a container has little water (0.4L or
less), a kettle is in condition to have been started.
Instructions
LCD : OFF 
• LED : Flashing (“Long Boil / Reboil”LED, "
Keep Warm
" LED)
Alternation flashing of 0.2 seconds
• Heater : OFF
• Others:It does not take "Select" button, “Timer” button.
Return movement
When it pressed the “Long Boil / Reboil” button or when the
disconnection of the sensor restored it..
5.3.2.
Bottom sensor disconnection
Shift condition
When it detects bottom sensor disconnection.
Instructions
LCD : Lighting (H1)
• LED : Flashing (“Long Boil / Reboil” LED, "VIP 
Keep Warm
"
LED) for 0.1 seconds ON / 0.3 second OFF sequentially
flashing.
• Heater : OFF
• Others : -
Return movement
When the disconnection of the sensor restored it or when a
breakdown made them return by simultaneous influence of
“Long Boil / Reboil” button and  “Select / Cleaning(Press 3s)”
button.
5.3.3.
Temperature input extraordinary 
mode
Shift condition
When boiling couldn't be detected even if 120 minutes
passed from starting.
Instructions
LCD : Lighting (H3)
• LED : Flashing (“Long Boil / Reboil” LED, "VIP 
Keep Warm
"
LED) for 0.1 seconds ON / 0.3 second OFF sequentially
flashing.
• Heater : OFF
• Others : -
Return movement
When the disconnection of the sensor restored it or when a
breakdown made them return by simultaneous influence of
“Long Boil / Reboil” button and  “Select / Cleaning(Press 3s)”
button.