WV-NW470S, WV-NW474SE - Panasonic Video Monitoring Service Manual (repair manual). Page 9

Read Panasonic WV-NW470S / WV-NW474SE Service Manual online

2-1
1. Test Equipment Required
The following Test Equipments are required for Adjust-
ment of the Colour CCTV Cameras WV-NW470S/WV-
NW474SE.
8
Oscilloscope
8
Frequency Counter
8
Vectorscope
8
Underscanned Colour Video Monitor
8
12 V DC/24V AC Power Supply Unit
8
Personal Computer (IBM PC/AT type or equivalent)
8
Standard Straight RS-232C Cable
8
Lux Meter
8
Lighting (140 footcandles (1 400 lx), Colour Temperature
3 200°K)
8
Colour Temperature Conversion Filters
Recommended manufacturer and part numbers are
shown in Table 1-1.
Table 1-1
8
Radiation Chart
8
Logarithmic Gray Scale Chart 
(Part Number: YWV2310RB99)
8
Colour Chip Chart (Part Number: YWV2100RB98)
8
White Chart or White Paper
8
Remote Electric Variable Resistor (E. V. R.) Adjustment Kit
as shown in Fig. 1-1. (Part Number: YWV0EA1174AN) 
Fig. 1-1
ADJUSTMENT PROCEDURE
Conversion
KENKO
KODAK
3 200°K 
→ 
5 100°K C12
80B
3 200°K 
→ 
6 500°K C4 and C12
80B and 80C
2. Disassembling Procedure for
Adjustment
8
Referring to Fig. 2-1, loosen the Tamperproof Screws (x
3) by using the Tamperproof Screw Bit (Supplied as a
Standard Accessory) that secure the Dome Cover and
remove the Dome Cover in the direction of the arrow from
the Camera Unit.
8
Referring to Fig. 2-2, remove two screws that secure the
Switch Board from the Camera Unit.
8
Remove the Pan Lock Screw that secure the Main Unit.
Fig. 2-1
Fig. 2-2
Tamperproof Screws
Dome Cover
Remove two Screws.
Pan Lock Screw
Switch Board
Main Unit
Camera