WV-NW470S, WV-NW474SE - Panasonic Video Monitoring Service Manual (repair manual). Page 7

Read Panasonic WV-NW470S / WV-NW474SE Service Manual online

1-3
DIP SW SETTING
• The default setting of SW501 on the Main Board is as fol-
lows;
INITIALIZING
You can reset the following data back to the factory default set-
tings.
Camera Setup
Setup Menu (PC oriented)
HTML files
Initializing the Camera Menu
• Move the cursor to CAMERA RESET.
• Hold down [Left], [Right], and [SET] buttons simultaneously
for 2 seconds on the camera, or click the All Reset button on
your computer display.
Initializing the Setup Menu
• In the power-on state, press the [Up] and [Down] buttons
simultaneously while holding down the button A.
Hold down the button A for 15 seconds. It will take about 10
seconds to complete the initializing. Be sure to continue sup-
plying power to the camera while initializing.
Notes:
• Clock calibration is required even after initializing the
setup menu.
• Try again if the previous initializing failed.
Initializing HTML Files
• In the power-on state, press the side panel buttons, [Up] and
[Down] simultaneously while holding down the button B.
Hold down the button B for 15 seconds. It will take about 10
seconds to complete the initializing. Be sure to continue sup-
plying power to the camera while initializing.
Notes:
• Never press both the buttons A and B at a time.
• Try again if the previous initializing failed.
IC502
SW501
<SW501>
1
2
O
N
Main Board
(Component Side)
Page of 54
Display