WJ-SX550 - Panasonic Video Monitoring Service Manual Supplement (repair manual). Page 52

Read Panasonic WJ-SX550 Service Manual Supplement online

– 49 –
403 LED D2 On Check
8
Factory use only.
404 LED D2 Off Check
8
Factory use only.
405 LED D3 On Check
8
Factory use only.
406 LED D3 Off Check
8
Factory use only.
407 LED D22 On Check
8
Factory use only.
408 LED D22 Off Check
8
Factory use only.
409 LED D23 On Check
8
Factory use only.
410 LED D23 Off Check
8
Factory use only.
411 LED D24 On Check
8
Factory use only.
412 LED D24 Off Check
8
Factory use only.
413 LED D25 On Check
8
Factory use only.
414 LED D25 Off Check
8
Factory use only.
415 7 Seg LED Continuous Display Check
8
Enter the Instruction Code 415 by the 10-key or
Instruction Code 15 by the SW11.
8
Press the GO key or press the SW2.
8
First 10's digit of 7 Seg LED should be displayed from 0
to F for 500 msec then 1's digit of 7 Seg LED should be
displayed from 0 to F continuously.
416 Pin 1 of CN5 (7 Seg LED) Output Check
8
Factory use only.
417 Pin 2 of CN5 (7 Seg LED) Output Check
8
Factory use only.
418 Pin 3 of CN5 (7 Seg LED) Output Check
8
Factory use only.
419 Pin 4 of CN5 (7 Seg LED) Output Check
8
Factory use only.
420 Pin 5 of CN5 (7 Seg LED) Output Check
8
Factory use only.
421 Pin 6 of CN5 (7 Seg LED) Output Check
8
Factory use only.
422 Pin 7 of CN5 (7 Seg LED) Output Check
8
Factory use only.
423 Pin 8 of CN5 (7 Seg LED) Output Check
8
Factory use only.
424 Pin 9 of CN5 (7 Seg LED) Output Check
8
Factory use only.
425 Pin 10 of CN5 (7 Seg LED) Output Check
8
Factory use only.
426 Pins 1 to 10 of CN5 (7 Seg LED) Output
Release Check
8
Factory use only.
427 Alarm Input Check (Does not automatic
recovery to Idle mode)
8
Enter the Instruction Code 427 by the 10-key or
Instruction Code 27 by the SW11.
8
Press the GO key or press the SW2.
8
Supply the Alarm signals 1 to 64 (connect to ground) to
the Alarm Input Connectors CN3 and CN4 on the Alarm
Board.
8
The Alarm signals are memorized sequentially, and then
the Data "STX ALM 01 - 64 ETX" is transmitted to the
Serial Interface line and these numbers are displayed on
the 7 Seg LED sequentially.
8
Execute the 499 Instruction by 10-key or press the ACK
RESET key of the WV-CU550, or press the Reset Switch
SW3 if the Self Check Function is done by the WJ-SX550
alone for a return to the Idle mode.
Page of 60
Display