GP-MF622E, GP-MF130E - Panasonic Video Monitoring Service Manual (repair manual). Page 9

Read Panasonic GP-MF622E / GP-MF130E Service Manual online

– 6 –
(4) Pedestal Adjustment
Test Point : Pin 4 of CN1 (VIDEO OUT)
Rear section of the Main Board
Adjust :
VR3(PEDESTAL CONTROL)
Rear section of the Main Board
Mount the Cap on the Lens.
Connect the Oscilloscoper to Pin 4 of CN1.
Trigger the Oscilloscope at H-rate.
Adjust VR3 so that the Pedstal signal level becomes 50 ±
10mV as shown in Fig. 5-3.
Remove the Cap from the Lens.
(5) Video Gain Adjustment
Test Point : Pin 4 of CN1 (VIDEO OUT)
Rear section of the Main Board
Adjust :
VR4(VIDEO GAIN)
Process section of the Main Board
Mount the Zoom Iris Lens on the Lens.
Aim the Camera at Logarithmic Gray Scale Chart.
Set the Lighting and Lens Iris at 2,000 lux and F16.
Connect the Oscilloscoper to Pin 4 of CN1.
Trigger the Oscilloscope at H-rate.
Turn VR5 (MANUAL GAIN CONTROL) on the Rear
Section of the Main Board fully counterclockwise.
Adjust VR4 so that the Video signal level becomes 700 ±
30 mVp-p as shown in Fig. 5-4.
Fig. 5-4
Mount the ND2 Filter on the Lens.
Turn VR5 (MANUAL GAIN CONTROL) on the Rear
Section of the Main Board fully clockwise.
50 
±
 10 mVp-p
Fig. 5-3
Confirm that the Video signal level becomes more than
700 mV) as shown in Fig. 5-4.
Return VR5 from fully clockwise to fully counter-
clockwise.
(6) V
SUB
Fine Adjustment
Test Point : Pin 4 of CN1 (VIDEO OUT)
Rear section of the Main Board
Adjust :
VR1(V
SUB
)
TG/SG section of the Main Board
Aim the Camera at the 40-watt Lamp placed in the dark
background.
Set the Lens Iris at F1.4.
If the blooming and noise appear on the Video Monitor as
shown in Fig. 5-6 (No Good), readjust VR1.
Note : 
VR1 should be adjusted to the point where the blooming
just disappears and minimize the smear as shown in Fig.
5-6.(Good)
Do not adjust VR1 more than the point.
If readjust VR1, must be readjusted from the adjustment
steps (4) through (5).
Fig. 5-6
(7) PLL VCO Adjustment
Test Point : TP2 (VCO)
TG/SG section of the Main Board
Adjust :
L1(VCO) TG/SG section of the Main Board
Supply the Black Burst or Composite Video signal to the
Camera Connector on the Rear Panel of the Camera.
Connect the Digital Voltmeter to TP2.
Adjust L1 to obtain 2.5 ± 0.2 V.
No Good
Good
LOCATION OF TEST POINT AND ADJUSTING CONTROLS
[CCD section]
[Process section]
[TG/SG section]
[Power section]
[Rear section]
(Component side)
(Pattern side)
(Component side)
(Pattern side)
(Pattern side)
(Pattern side)
4
VR4
VIDEO 
GAIN
L1
VCO
TP2
(VCO)
VR1
V
SUB
VR2
RESET
BIAS
6
1
2
3
4
5
6
1
2
3
4
5
OFF
ON
OFF
ON
SW1
SW1
SW1
TP3
(V
SUB
)
TP4
(RESET
 PULSE)
C67
+
(+5.0V)
VR6
+5.1V
ADJ
VR3 VR5
CN1
CN2
SW1
VIDEO
12P
VR3
PEDESTAL
CONTROL
VR5
MANUAL 
GAIN 
CONTROL
CN1
CAMERA 
CONNECTOR
CN2
VIDEO
OUTPUT
CONNECTOR
700 
±
 30 mVp-p
300 
±
 30 mVp-p
Page of 16
Display

Click on the first or last page to see other GP-MF622E / GP-MF130E service manuals if exist.