GP-MF622E, GP-MF130E - Panasonic Video Monitoring Service Manual (repair manual). Page 8

Read Panasonic GP-MF622E / GP-MF130E Service Manual online

– 5 –
4.3. Setting Up for Standard Picture
The adjustment should be done after 10 minutes warm
up. 
Set the Logarithmic Gray Scale Chart.
Mount the Iris Lens (HF16A) on the Camera. 
Incident light of 2,750 ± 150 lux on the Logarithmic Gray
Scale Chart.
Aim the Camera at the Logarithmic Gray Scale Chart. 
Set the Camera so that the Logarithmic Gray Scale Chart
becomes full picture on the Underscanned Black and
White Video Monitor. 
Adjust the Lens Iris to obtain correct focal point.
5. Adjustment Procedure
Refer to the Location of the Test Points and Adjusting
Controls on page 6.
(1) +5.0V Adjustment
Test Point : +Polarity of C67
Power section of the Main Board
Adjust :
VR6 (+5.1V ADJ)
Power sction of the Main Board
Connect the Digital Voltmeter to + Polarity of C67.
Adjust VR6 to obtain 5.1 ± 0.05V DC.
(2) Reset Bias Adjustment
Test Point : TP4 (RESET PULSE)
CCD section of the Main Board
Adjust :
VR2 (RESET BIAS)
TG/SG section of the Main Board
Connect the Oscilloscope to TP4.
FOR GP-MF622E, adjust VR2 to obtain indicated Voltage
(Rank)  ± 0.1V on the CCD section of the Main Board as
shown in Table 5-1 and Fig. 5-1.
Rank
1
2
3
4
5
6
7
Voltage
1.0
1.5
2.0
2.5
3.0
3.5
4.0
Reset Bias
Ground
Fig. 5-1
FOR GP-MF130E, adjust VR2 to obtain 0.75  ± 0.1V as
Reset Bias 
(0.75 
±
 0.1V)
Ground
Fig. 5-2
(3) Vsub Coarse Adjustment
Test Point : TP3 (V
SUB
) CCD section of the Main Board
Adjust :
VR1 (V
SUB
)
TG/SG section of the Main Board
8
Connect the Digital Voltmeter to TP3.
8
FOR GP-MF622E, adjust VR1 to obtain indicated Voltage
(Rank) ± 0.1V on the CCD section of the Main Board as
shown in Table 5-2.
8
FOR GP-MF130E, adjust VR1 to obtain indicated Voltage
(Rank) ± 0.1V on the CCD section of the Main Board as
shown in Table 5-3.
1st Rank     2nd Rank   
Example :  95 
9.5V
E3 
14.3V
Rank
E
f
G
h
J
K
L
m
N
P
Voltage 9.0
9.5 10.0 10.5 11.0 11.5 12.0 12.5 13.0 13.5
Rank
Q
R
S
T
U
V
W
X
Y
Z
Voltage 14.0 14.5 15.0 15.5 16.0 16.5 17.0 17.5 18.0 18.5
Table 5-2
1st Rank
3
4
5
6
7
8
9
A
B
C
Voltage
3.0
4.0
5.0
6.0
7.0
8.0
9.0 10.0 11.0 12.0
1st Rank
D
E
F
G
H
I
J
K
L
Voltage 13.0 14.0 15.0 16.0 17.0 18.0 19.0 20.0 210
2nd Rank
0
1
2
3
4
5
6
7
8
9
Voltage
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
Table 5-3
Table 5-1
Page of 16
Display

Click on the first or last page to see other GP-MF622E / GP-MF130E service manuals if exist.