GP-MF622E, GP-MF130E - Panasonic Video Monitoring Service Manual (repair manual)

gp-mf622e, gp-mf130e service manual
Model
GP-MF622E GP-MF130E
Pages
16
Size
584.63 KB
Type
PDF
Document
Service Manual
Brand
Device
Video Monitoring / CAMERA
File
gp-mf622e-gp-mf130e.pdf
Date

Read Panasonic GP-MF622E / GP-MF130E Service Manual online

ORDER NO. AVS9810129C8
Machine Vision Camera
Machine Vision B/W CCD Camera
GP-MF622E
GP-MF130E
c 1 9 9 8     M a t s u s h i t a   C o m m u n i c a t i o n   I n d u s t r i a l   C o . ,   L t d .
A l l   r i g h t s   r e s e r v e d .   U n a u t h o r i z e d   c o p y i n g   a n d
d i s t r i b u t i o n   i s   a   v i o l a t i o n   o f   l a w .
SPECIFICATIONS
GP-MF622E
Pick-up Device :
Inter Line Transfer type CCD with 752 (H) x 582 (V) pixels.
Image Size :
1/2” (7.95 (H) x 6.45 (V) mm)
2 : 1 interlace 1-line interlace (Frame accumulation)
2 : 1 interlace 2-line interlace (Field accumulation)
Synchronization :
Internal or External (Selectable Automaticy)
Internal : Built-in sync generator
External : 4.0 V[p-p]/75 
Horizontal drive and Vertical drive pulses
for 2 : 1 interlace
External Reset :
External signal (4.0 V[p-p]/75 
, negative) supplied to EXT VD IN connector can be used as reset signal
Horizontal Resolution : 
560 lines at center
Minimum Illumination : 
1.0 lx (0.1 foot-candles), (F1.4, Manual Gain Max (+6 dB), 
γ
OFF, 2 : 1 interlace, without shutter)
Signal to Noise Ratio:
54 dB Typical (Manual Gain OFF (0 dB),  
γ
OFF, 2:1 interlace without shutter)
Gamma :
1.0
Gain Selection :
0 - 6 dB (Adjustable by Manual Gain Control on rear panel)
Electronic Shutter :
10-step (1/120 s to 1/96 000 s) at normal
7-step (1/2 000 s to 1/96 000 s) at Shutter Trigger Mode B.
4-step (1/2 000 s to1/30 000 s) at Shutter Trigger Mode C.
Lens Mount :
C-Mount
Vibration Resistance :
10 G (10 Hz - 150 Hz) (2 hours each for three axes)
Shock Resistance :
80 G (IEC 68) *IEC=International Electronical Technical Commission
Power Source :
DC + 12 V, 170 mA
Ambient Temperature :
10˚C - +50˚C (14˚F - 122˚F)
Dimensions :
29(W) x 29(H) x 65(D) mm [1-1/8”(W) x 1-1/8”(H) x 2-13/16”(D)]
Weight :
86 
g
(0.19 lbs.) (Camera Only)
Dimensions and weight indicated are approximate values.
Specifications are subject to change without notice.
GP-MF622E
GP-MF130E
GP MF622E/GP MF130E
This service information is designed for experienced repair technicians only and is not designed for use by the
general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to
service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any
attempt to service or repair the product or products dealt with in this service information by anyone else could
result in serious injury or death.
WARNING
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION:
TO REDUCE THE RISK OF ELECTRIC SHOCK, 
DO NOT REMOVE COVER (OR BACK). NO USER 
SERVICEABLE PARTS INSIDE.
REFER SERVICEING TO QUALIFIED SERVICE
PERSONNEL.
This  symbol  warns  the  user  that  uninsuland  voltage 
within the  unit  may  have  sufficient  magnitude  to  cause   
electric
shock. Therefore,  it  is dangerous to make any kind of 
contact with any inside part of this unit.
This symbol alerts the user that impotant literature concerning 
the operation and maintenance of this has been included.
Therefore,  it  should  be  read  carefully  in  order  to avoid 
T
here are special components used in this equipment which are important for safety. These parts are indicated 
by the    mark  on  the  schematic diagram and  the replacement parts list. It is essential that these critical 
parts should be replaced with manufacturer's specified parts to prevent X-radiation, shock, fire, or other hazards.
Do not modify the original design without permission of manufacture.
IMPORTANT SAFETY NOTICE
GP-MF130E
Pick-up Device :
Inter Line Transfer type CCD with 752 (H) x 582 (V) pixels.
Image Size :
1/3” (6.00 (H) x 4.96 (V) mm)
2 : 1 interlace 1-line interlace (Frame accumulation)
2 : 1 interlace 2-line interlace (Field accumulation)
Synchronization :
Internal or External (Selectable Automatically)
Internal : Built-in sync generator
External : 4.0 V[p-p]/75 
Horizontal drive and Vertical drive pulses
for 2 : 1 interlace
External Reset :
External signal (4.0 V[p-p]/75 
, negative) supplied to EXT VD IN connector can be used as reset signal
Horizontal Resolution : 
560 lines at center
Minimum Illumination : 
1.0 lx (0.1 foot-candles), (F1.4, Manual Gain Max (+6 dB), 
γ
OFF, 2 : 1 interlace, without shutter)
Signal to Noise Ratio:
54 dB Typical (Manual Gain OFF (0 dB),  
γ
OFF, 2:1 interlace without shutter)
Gamma :
1.0
Gain Selection :
0 - 6 dB (Adjustable by Manual Gain Control on rear panel)
Electronic Shutter :
10-step (1/120 s to 1/96 000 s)
Lens Mount :
C-Mount
Vibration Resistance :
10 G (10 Hz - 150 Hz) (2 hours each for three axes)
Shock Resistance :
80 G (IEC 68) *IEC=International Electronical Technical Commission
Power Source :
DC + 12 V, 170 mA
Ambient Temperature :
10˚C - +50˚C (14˚F - 122˚F)
Dimensions :
29(W) x 29(H) x 65(D) mm [1-1/8”(W) x 1-1/8”(H) x 2-13/16”(D)]
Weight :
86 
g
(0.19 lbs.) (Camera Only)
Dimensions and weight indicated are approximate values.
Specifications are subject to change without notice.
OPTIONAL ACCESSORIES
Camera Cable
GP-CA34
GP-CA33
GP-CA59
GP-CA60
CONTENTS
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS ................................................................................... 1
ADJUSTMENT PROCEDURE...................................................................................................................................... 3
LOCATION OF TEST POINTS AND ADJUSTING CONTROLS ................................................................................. 6
SCHEMATIC DIAGRAM .............................................................................................................................................. 7
CONDUCTOR VIEW .................................................................................................................................................... 8
EXPLODED VIEW  ....................................................................................................................................................... 9
REPLACEMENT PARTS LIST .................................................................................................................................. 10
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS
– 1 –
12P
VIDEO
622
ON
OFF
1
6
1
6
7
8
9
0
A
ON
OFF
1
6
B
C
D
E
F
G
3
4
2
5
1. 1/2” Manual Iris Lens (Sold Separately)
2. Camera Connector (12-pin) 
This is connected with the optional Camera Cable GP-CA34 ,
GP-CA33, GP-CA59 or GP-CA60.
3. Pedestal Control
This controls the pedestal level from 0 mV to 100 mV.
4. Manual Gain Control
This controls the gain level from 0 to 6 dB.
5. Video Output Connector
This connector is used to connect with the VIDEO IN connector
of the monitor.
6. Switch 1 No.1 (1/ON) 1
ON
This switch selects the Field or Frame Accumulation.
ON  : Field Accumulation
OFF: Frame Accumulation
7. Switch 1 No.2 (2/ON) 2
ON
8. Switch 1 No.3 (3/ON) 3
ON
9. Switch 1 No.4 (4/ON) 4
ON
10. Switch 1 No.5 (5/ON) 5
ON
These switches (Switch 1 No. 2, 3, 4, and 5) are used to set the
shutter speed. The shutter speed changes according to the
mode which is set by the switch. (See following pages to select
mode by settings for Switch 2.) 
1
9
2 10 8
3 11
7
12
4
5
6
Pin No.
Description
1
Ground
2
+12V IN
3
Ground for Video Out
4
Video Out
5
Ground for HD
6
HD IN
7
VD/V reset/V cont IN
8
Ground
9
No connection
10
No connection
11
No connection
12
Ground for VD
CAUTION: CONNECT THIS TO A DC 12V
CLASS 2 POWER SUPPLY 
ONLY.
The shutter speed can be set as below:
11. Switch 1 No.6 (6/ON) 6
ON
This switch is not available for this model.
12. Switch 2 No.1 (1/ON) 1
ON
13. Switch 2 No.2 (2/ON) 2
ON
These switches (Switch 2 No.1 and 2) are used to set the
mode. You can select the mode from A, B, and C mode.
The mode can be set as below:
14. Switch 2 No.3 (3/ON) 3
ON
When V reset is selected (Switch 2 No.1 is ON and No.2 is
OFF), this switch selects B mode or C mode.
B mode: V reset Latch off
C mode: V reset Latch on
15. Switch 2 No.4 (4/ON) 4
ON
When V cont is selected (Switch 2 No.1 is OFF and No.2 is
ON), set this switch to ON and Switch 2 No.6 to OFF.
16. Switch 2 No.5 (5/ON) 5
ON
This switch turns on or off the termination for HD signal with 75 
.
17. Switch 2 No.6 (6/ON) 6
ON
This switch turns on or off the termination for VD signal with 75 
.
When V cont is selected (Switch 2 No.1 is OFF and No.2 is
ON), set this switch to OFF and Switch 2 No.4 to ON.
Switch 1
Mode
No. 2 No. 3 No. 4 No. 5
OFF OFF OFF OFF
ON
OFF OFF OFF
OFF
ON
OFF OFF
ON
ON
OFF OFF
OFF OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
OFF
OFF OFF OFF
ON
ON
OFF OFF
ON
OFF
ON
OFF
ON
Other Combinations
A
B
C
Normal
1/2 000 1/2 000
1/120 1/2 000 1/2 000
1/500 1/2 000 1/2 000
1/1 000 1/2 000 1/2 000
1/2 000 1/2 000 1/2 000
1/4 000 1/4 000 1/4 000
1/8 000 1/8 000 1/10 000
1/16 000 1/16 000 1/30 000
1/32 000 1/32 000 Not Specified
1/64 000 1/64 000 Not Specified
1/96 000 1/96 000 Not Specified
Not Specified Not Specified Not Specified
Switch 2
Mode
No. 1
OFF
ON
OFF
Other Combinations
No. 2
OFF
OFF
ON
A mode : Internal, HD/VD
B, C mode : V reset
D mode : V cont
Not Specified
GP-MF622E
Page of 16
Display

Download Panasonic GP-MF622E / GP-MF130E Service Manual (Repair Manual)

Here you can read online and download Panasonic GP-MF622E / GP-MF130E Service Manual in PDF. GP-MF622E / GP-MF130E service manual will guide through the process and help you recover, restore, fix, disassemble and repair Panasonic GP-MF622E / GP-MF130E Video Monitoring. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.