3-14 Change the positions of the DIP switches on the iris
camera as shown in Fig. 15.
Fig. 15
* The wrong switch setting may prevent the iris camera
from booting properly.
3-15 Install the administration software BM-ES300 on the
computer.
4. Adjusting Conditions
Personal computer
The administration software BM-ES300 must have been
installed, and [IrisMngSrv] set ready for start.
How to check
<<Windows XP>>
1. Open the control panel on the computer screen.
2. Select the management tool on the control panel.
3. Select [Service] from the management tools.
4. Check that [IrisMngSrv] of the selected service has start-
ed.
5. Position Sensor Adjustment
Note: This position sensor adjustment is required in the
following cases;
1. Replacing the Position Sensor
2. Replacing the Main Board
5-1 Turn on the power.  (It takes about a minute to start.)
5-2 Double-click [IrisCmrAdjustKno.exe] that was expanded
in Step 3-1.
The camera setting tool screen shown in Fig. 16 appears
on the monitor.
Fig. 16
– 2-5 –
5-3 Press the [Environment Settings] button e on the adjust-
ing tool screen.  The environment setting screen shown
in Fig. 17 appears on the monitor.
5-4 Enter the camera ID and IP address that were set in the
iris camera and confirmed in Step 3-10 in the boxes q
and w on the environment setting screen.
Fig. 17
5-5 Confirm that the check mark has been removed from
[Output result file] e on the environment setting screen,
and press the [Apply] button u.
5-6 Press the [Manual Execute] button q on the adjusting
tool screen shown in Fig. 16.
5-7 The manual execution screen shown in Fig. 19 appears
on the monitor.