CW-C241SE - Panasonic Air Conditioner Service Manual (repair manual). Page 6

Read Panasonic CW-C241SE Service Manual online

CW-C241SE
– 5 –
HOW TO INSTALL
3. Drain Water....
To get the maximum cooling efficiency this air conditioner is designed to splash the condensate on the condenser coil.
This method is called “Slinger-Up System”.
If the splashing sound annoys you, you can provide an outside drain by using the following procedure which may, however cause
a small loss of performance.
1. Slide out the chassis from the cabinet.
2. Remove the rubber plug from the body base plate.
3. Install the drain pan prepared in the accessory kit to the corner of the cabinet with 2 screws.
4. Connect the drain hose to the outlet on the drain pan bottom.
5. Slide the chassis into its original place in the cabinet.
Note: Drain hose or tubing can be purchased locally to satisfy your particular needs.
4. Plug line cord into wall receptacle.
<230–220V, 50Hz>
Power should be from independent circuit.
EXTERNAL VIEW
INTERNAL VIEW
BOTTOM-SIDE VIEW WITH DRAIN
PAN AND HOSE IN PLACE
SCREWS
DRAIN PAN
DRAIN HOSE
Install drain pan at left corner of cabinet.
Page of 12
Display

Click on the first or last page to see other CW-C241SE service manuals if exist.