DIMENSIONS
– 2 –
ITEM
CW-C241SE
A
Width
26"
(660)
B
Height
16 – 7/8"
(428)
C
Depth
28 – 3/4"
(730)
D
26 – 25/32"
(680)
E
1 – 31/32"
(50)
F
11 – 13/16"
(300)
G
2 – 3/64"
(75)
I
3/64"
(15)
J
10 – 13/16"
(288)
K
15 – 11/32" (389.6)
L
12 – 17/32"
(318)
M
3 – 5/32"
(80)
N
3 – 35/64"
(90)
Unit : (mm)
K
N
N
J
B
A
FRONT VIEW
TOP VIEW
M
L
Panasonic
E
F
G
2-3/32"
(53)
13-25/32"
(350)
C
I
SIDE VIEW
D
G
WIRING DIAGRAM
ORANGE
YELLOW
Resistance of Fan Motor windings and rated Capacitor
Resistance of Compressor windings and rated Capacitor
POWER SUPPLY CORD
1Ø, 230-220V, 50Hz
COMPRESSOR
1
2
1
2
4
0
MAIN SWITCH
AIR SWING
SELECT SWITCH
AIR SWING
MOTOR
YELLOW/GREEN
3
BROWN
YELLOW/GREEN
BLUE
FUSE (5A)
1          P
BLUE
BLUE
BLACK
WHITE
WHITE
BLACK
BLUE  BLUE
WHITE
RED
BLUE
CAPACITOR
RED
BLUE
R            S
C
YELLOW
CAPACITOR
THERMOSTAT
(LOW TEMP.)
THERMOSTAT
(TEP. CONTROL)
FOR MODEL
CW-C241SE
ONLY
COMP. TERMINAL
YELLOW (C)
BLUE (R)
RED (S)
TRADE MARK
BROWN
FAN MOTOR
CW-C241SE
Connection
2JS438D4AA02
C-R
0.95
C-S
4.39
CAPACITOR
CWA31539
45µF/370VAC
CW-C241SE
Connection
CWA92125
BLUE–YELLOW
18.8
YELLOW–ORANGE
6.25
RED–YELLOW
51.5
CAPACITOR
CWA31244
3µF/400VAC
* Resistance at 20°C of Ambient Temp.
Page of 12