Unit
Indoor Unit
Outdoor Unit
Fan Motor
Description
Cross-flow Fan
Propeller Fan
Material
AS + Glass Fiber 20%
PP Resin
Type
Induction (4-poles)
Induction (6-poles)
Input
W
60.5 - 66.0
66 - 74.8
Rated
Output
W
15
30
Fan Speed Low
rpm
Cooling; 780 - 780
Heating; 840 - 840
Heating; 840 - 840
—
Medium
rpm
Cooling; 920 - 920
Heating; 920 - 920
Heating; 920 - 920
—
High
rpm
Cooling; 1,050 - 1,050
Heating; 1,220 - 1,220
Heating; 1,220 - 1,220
800 - 830
SuperHigh
rpm
Cooling; 1,220 - 1,220
Heating; —
—
Heat Exchanger
Description
Evaporator
Condenser
Tube material
Copper
Copper
Fin material
Aluminium (Pre Coat)
Aluminium (Blue Coat)
Fin Type
Slit Fin
Corrugated Fin
Row / Stage
(Plate fin configuration, forced draft)
2 × 15
2 × 23
FPI
21
17
Size (W × H × L)
mm
610 × 315 × 25.4
585.7
557.1
557.1
× 484 × 36.4
Refrigerant Control Device
—
Capillary Tube
Refrigeration Oil
(cm
3
)
—
ATMOS M60 OR SUNISO 4GDID
Refrigerant (R22)
g (oz)
—
690 (24.3)
Thermostat
—
—
Protection Device
—
Overload Protector
Capillary Tube
Length
mm
—
Cooling; 330, Heating; 566
Flow Rate
l/min
—
Cooling; 20.6, Heating; 9.5
Inner Diameter
mm
—
Cooling; 1.7, Heating; 1.4
Air Filter
Material
Style
Style
P.P.
Honeycomb
—
Capacity Control
Capillary Tube
Compressor Capacitor
µF, VAC
—
20 µF, 370VAC
Fan Motor Capacitor
µF, VAC
1.5 µF, 440VAC
2.0 µF, 440VAC