CS-A7DKD, CU-A7DKD, CS-A9DKD, CU-A9DKD, CS-A12DKD, CU-A12DKD - Panasonic Air Conditioner Service Manual (repair manual). Page 11

Read Panasonic CS-A7DKD / CU-A7DKD / CS-A9DKD / CU-A9DKD / CS-A12DKD / CU-A12DKD Service Manual online

Unit
Indoor Unit
Outdoor Unit
Fan Motor
Description
Cross-flow Fan
Propeller Fan
Material
AS + Glass Fiber 20%
PP Resin
Motor
Type
Induction (4-poles)
Induction (6-poles)
Input
W
60.5 - 66.0
71.5 - 80.3
Rated
Output
W
15
31
Fan Speed Low
rpm
Cooling; 900 - 900
Heating; 960 - 960
Medium
rpm
Cooling; 1,120 - 1,120
Heating; 1,120 - 1,120
High
rpm
Cooling; 1,280 - 1,280
Heating;1,310 - 1,310
845 - 860
SuperHigh
rpm
Cooling; 1,310 - 1,310
Heating; —
Heat Exchanger
Description
Evaporator
Condenser
Tube material
Copper
Copper
Fin material
Aluminium (Pre Coat)
Aluminium (Blue Coat)
Fin Type
Slit Fin
Corrugated Fin
Row / Stage
(Plate fin configuration, forced draft)
2 × 15
2 × 24
FPI
21
16
Size (W × H × L)
mm
610 × 315 × 25.4
720 × 504 × 36.38
Refrigerant Control Device
Capillary Tube
Refrigeration Oil
(cm
3
)
ATMOS M0 OR SUNISO 4GDID
Refrigerant (R-22)
g (oz)
1,080 (38.1)
Thermostat
Protection Device
Capillary Tube
Length
mm
Cooling; 630, Heating; 455
Flow Rate
l/min
Cooling; 6.5, Heating; 13.6
Inner Diameter
mm
Cooling; 1.2 Heating; 1.5
Air Filter
Material
Style
P.P.
Honeycomb
Capacity Control
Capillary Tube
Compressor Capacitor
µF, VAC
35 µF, 370VAC
Fan Motor Capacitor
µF, VAC
1.5 µF, 440VAC
2.0 µF, 440VAC
Note:
 • 
Specifications are subjected to change without prior notice for further improvement.
11
CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12DKD CU-A12DKD /
Page of 88
Display