3 Product Specifications
3.1. CS-A7DKD CU-A7DKD
Unit
Indoor Unit
Outdoor Unit
Power Source (Phase, Voltage, Cycle)
ø, V, Hz
Single, 220 - 230, 50
Cooling Capacity
kW (BTU/h)
2.00 - 2.00 (6,820 - 6,820)
Heating Capacity
kW (BTU/h)
2.10 - 2.10 (7,160 - 7,160)
Moisture Removal
l/h (Pint/h)
1.3 (2.7)
Airflow Method
OUTLET
INTAKE
SIDE VIEW
TOP VIEW
Air Volume
Lo
m
3
/min (cfm)
Cooling; 5.8 (205) - 5.8 (205)
Heating; 6.2 (219) - 6.2 (219)
Me
m
3
/min (cfm)
Cooling; 6.8 (241) - 6.8 (241)
Heating; 6.8 (241) - 6.8 (241)
Hi
m
3
/min (cfm)
Cooling; 7.8 (280) - 7.8 (280)
Heating; 9.0 (320) - 9.0 (320)
Cooling; 29.5 (1,040) - 30.0
(1,060)
SHi
m
3
/min (cfm)
Cooling; 9.1 (320) - 9.1 (320)
Heating; —
Noise Level
dB (A)
Cooling; High 33 - 33, Low 26 - 26
Heating; High 36 - 36, Low 28 - 28
Cooling; High 46 - 47
Heating; High 48 - 49
Power level dB
Cooling; High 46 - 46
Heating; High 49 - 49
Cooling; High 61 - 62
Heating; High 64 - 65
Electrical Data
Input Power
kW
Cooling; 0.61 - 0.63
Heating; 0.50 - 0.525
Running Current
A
Cooling; 2.9 - 2.8
Heating; 2.4 - 2.4
EER
W/W (BTU/hW)
Cooling; 3.28 - 3.17 (11.2 - 10.8)
COP
- (BTU/hW)
Heating; 4.2 - 4.0 (14.3 - 13.6)
Starting Current
A
12.4
Piping Connection Port
(Flare piping)
inch
inch
G ; Half Union 3/8”
L ; Half Union 1/4”
G ; 3-way valve 3/8”
L ; 2-way valve 1/4”
Pipe Size
(Flare piping)
inch
inch
G ; (gas side) 3/8”
L ; (liquid side) 1/4”
G ; (gas side) 3/8”
L ; (liquid side) 1/4”
Drain
Hose
Inner diameter
mm
12
Length
mm
650
Power Cord
Length
m
1.9
Number of core-wire
3 (1.5 mm
2
)
Dimensions
Height
inch (mm)
11 - 1/32 (280)
20 - 3/32 (510)
Width
inch (mm)
31 - 15/32 (799)
25 - 19/32 (650)
Depth
inch (mm)
7 - 7/32 (183)
9 - 1/16 (230)
Net Weight
lb (kg)
20 (9.0)
53 (24)
Compressor
Description
Rotary (1 cylinder)
rolling piston type
Motor
Type
Induction (2-poles)
Rated
Output
W
550