CS-A7DKD, CU-A7DKD, CS-A9DKD, CU-A9DKD, CS-A12DKD, CU-A12DKD - Panasonic Air Conditioner Service Manual (repair manual). Page 4

Read Panasonic CS-A7DKD / CU-A7DKD / CS-A9DKD / CU-A9DKD / CS-A12DKD / CU-A12DKD Service Manual online

2.2. Indoor Unit
Automatic Operation Button
• Press for < 5 second to operate Automatic
operation mode. Used when the remote control
cannot be used.
• Press for 
 5 second to operate Cooling
operation mode and compressor force to on
(“beep” sound will heard). Used when test
running or servicing.
• Within 20 second of Cooling operation, press
continuously for
 5 second to enter various
setting mode. “beep, beep” sound will be heard.
(Used to toggle remote control signal receiving
sound or select remote control transmission
code).
AUTO
OFF / ON
Operation Indication Lamps (LED)
7 Minutes Time Save Control
• To reduce the built up humidity inside the room.
Anti-Dew Formation Control
• Anti-Dew Formation Control for indoor unit
discharge area.
Timer Operation
• Delay OFF/ON Timer control.
Powerful Operation
• Reaches the desired room temperature quickly.
Anti-Freezing Control
• To prevent indoor heat exchanger from freezing.
Random Auto Restart Control
• Unit will be restarted, when resume from power
failure, at previous setting.
Indoor Fan Speed Control
• Manual control fan speed (High, Medium and
Low).
• Automatic fan speed.
• Vertical airflow control can be adjusted
automatically or manually by remote control.
• Horizontal airflow can be manually adjusted by
hand.
Airflow Direction Control
Time Delay Safety Control
• Restarting is inhibited for appro. 3 minutes.
Hot-Start Control
• To prevent cold air being discharge during
Heating operation starts.
Starting Current Control
• To reduce the starting current.
Anti Cold Draft Control
• To prevent the cold draft during Heating mode
operation in thermo off condition.
Operation Mode
• Heating, Cooling, Soft Dry and Automatic
Operation.
30 Minutes Time Save Control
• Heating operation only.
Quiet Operation
• To provide quiet operation.
Ionizer Operation
• Generate and discharge negative ion.
POWER
 
(Green) ............. Lights up in operation,
blinks in Automatic
Operation judging and
Hot Start operation.
TIMER
 
(Orange) ............ Lights up in Timer
Setting.
QUIET
 
(Orange) ............. Lights up in Quiet
Operation.
POWERFUL
 
(Orange) ...... Lights up in Powerful
Operation.
ION
 
(Green) .................. Lights up in Ionizer
Operation.
SUPER
ALLERU-BUSTER
 
(Blue) ... Lights up in operation.
4
CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12DKD CU-A12DKD /
Page of 88
Display

Click on the first or last page to see other CS-A7DKD / CU-A7DKD / CS-A9DKD / CU-A9DKD / CS-A12DKD / CU-A12DKD service manuals if exist.