Read Panasonic CS-A7DKD / CU-A7DKD / CS-A9DKD / CU-A9DKD / CS-A12DKD / CU-A12DKD Service Manual online
1 Features
2
2 Functions
3
2.1.
Remote Control
3
2.2.
Indoor Unit
4
2.3.
Outdoor Unit
5
3 Product Specifications
6
3.1.
CS-A7DKD CU-A7DKD
6
3.2.
CS-A9DKD CU-A9DKD
8
3.3.
CS-A12DKD CU-A12DKD
10
4 Dimensions
12
CS-A7DKD CU-A7DKD
CS-A9DKD CU-A9DKD
CS-A12DKD CU-A12DKD
CS-A9DKD CU-A9DKD
CS-A12DKD CU-A12DKD
4.1.
Indoor Unit & Remote Control
12
4.2.
Outdoor Unit
13
5 Refrigeration Cycle Diagram
14
6 Block Diagram
15
7 Wiring Diagram
17
8 Operation Details
19
8.1.
Heating Operation
19
8.2.
Cooling Operation
20
8.3.
Soft Dry Operation
21
Air Conditioner
CONTENTS
Page
Page
Order No. MAC0501023C3
8.4.
Automatic Operation
22
8.5.
Operation Control
23
8.6.
Indoor Fan Speed Control
30
8.7.
Outdoor Fan Speed Control
32
8.8.
Vertical Airflow Direction Control
32
8.9.
Horizontal Airflow Direction Control
33
8.10. Powerful Operation
33
8.11. Quiet Operation
35
8.12. Ionizer Operation
37
8.13. Timer Control
38
8.14. Random Auto Restart Control
38
8.15. Remote Control Signal Receiving Sound
38
9 Operating Instructions
39
10 Installation Instructions
45
10.1. Safety Precautions
45
10.2. Attached accessories
47
10.3. Select the best location
47
10.4. Indoor/Outdoor Unit Installation Diagram
47
10.5. Indoor unit
48
10.6. Outdoor unit
51
11 2-way, 3-way Valve
56
11.1. Air Purging of the Piping and Indoor Unit
57
12 Servicing Information
63
12.1. Distinction Of Lead Free (PbF) Printed Circuit Board
63
12.2. Indoor Electronic Controllers Removal Procedures
63
•
High Efficiency
•
Compact Design
•
Wider range of horizontal discharge air.
•
Air Filter with function to reduce dust and smoke.
•
Automatic air swing and manual adjusted by Remote
Control for vertical airflow.
Control for vertical airflow.
•
Long installation piping.
−
CS/CU-A7DK, CS/CU-A9DK, long piping up to 10
meter.
meter.
−
CS/CU-A12DK, long piping up to 15 meter.
•
Supersonic Air Purifying Device with SUPER alleru-
buster.
buster.
−
Inactive various harmful airborne elements including
allergen, viruses and bacteria.
allergen, viruses and bacteria.
−
Generated supersonic waves enhance the ability to
collect dust and dirt in the air.
collect dust and dirt in the air.
12.3. Indoor Fan Motor And Cross Flow Fan Removal
Procedures
64
12.4. Auto OFF/ON Button
65
12.5. Remote Control Reset
66
13 Troubleshooting Guide
67
13.1. Refrigeration Cycle System
67
13.2. Relationship Between The Condition Of The Air
Conditioner And Pressure And Electric Current
68
13.3. Diagnosis Methods Of A Malfunction Of A Compressor
And 4-way Valve
68
14 Technical Data
69
14.1. Thermostat Characteristics
69
14.2. Operation Characteristics
70
15 Exploded View (Indoor Unit)
73
15.1. CS-A7DKD CS-A9DKD CS-A12DKD
73
16 Replacement Parts List (Indoor Unit)
74
17 Exploded View (Outdoor Unit)
75
17.1. CU-A7DKD CU-A9DKD
75
17.2. CU-A12DKD
76
18 Replacement Parts List (Outdoor Unit)
77
19 Electronic Circuit Diagram
79
19.1. Indoor Unit & Outdoor Unit
79
19.2. Remote Control
85
19.3. Print Pattern Indoor Unit Printed Circuit Board
86
19.4. Print Pattern Indicator & Receiver Printed Circuit Board
88
•
Quality Improvement
−
Random auto restart after power failure for safety restart
operation.
operation.
−
Gas leakage protection.
−
Prevent Compressor reverse cycle.
−
Inner protector to protect Compressor.
−
Noise prevention during soft dry operation.
−
Blue Coated Condenser for high resistance to corrosion.
•
Operation Improvement
−
Quiet mode to provide quiet operation.
−
Powerful mode to reach the desired room temperature
quickly.
quickly.
−
Ionizer control for generating negative ion in discharge
air.
air.
−
24-hour timer setting.
•
Serviceability Improvement
−
Removable and washable Front Panel.
1 Features
2
CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12DKD CU-A12DKD /
2 Functions
2.1. Remote Control
3
CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12DKD CU-A12DKD /
2.2. Indoor Unit
Automatic Operation Button
• Press for < 5 second to operate Automatic
operation mode. Used when the remote control
cannot be used.
cannot be used.
• Press for
≥
5 second to operate Cooling
operation mode and compressor force to on
(“beep” sound will heard). Used when test
running or servicing.
(“beep” sound will heard). Used when test
running or servicing.
• Within 20 second of Cooling operation, press
continuously for
5 second to enter various
setting mode. “beep, beep” sound will be heard.
(Used to toggle remote control signal receiving
sound or select remote control transmission
code).
(Used to toggle remote control signal receiving
sound or select remote control transmission
code).
AUTO
OFF / ON
Operation Indication Lamps (LED)
7 Minutes Time Save Control
• To reduce the built up humidity inside the room.
Anti-Dew Formation Control
• Anti-Dew Formation Control for indoor unit
discharge area.
Timer Operation
• Delay OFF/ON Timer control.
Powerful Operation
• Reaches the desired room temperature quickly.
Anti-Freezing Control
• To prevent indoor heat exchanger from freezing.
Random Auto Restart Control
• Unit will be restarted, when resume from power
failure, at previous setting.
Indoor Fan Speed Control
• Manual control fan speed (High, Medium and
Low).
• Automatic fan speed.
• Vertical airflow control can be adjusted
automatically or manually by remote control.
• Horizontal airflow can be manually adjusted by
hand.
Airflow Direction Control
Time Delay Safety Control
• Restarting is inhibited for appro. 3 minutes.
Hot-Start Control
• To prevent cold air being discharge during
Heating operation starts.
Starting Current Control
• To reduce the starting current.
Anti Cold Draft Control
• To prevent the cold draft during Heating mode
operation in thermo off condition.
Operation Mode
• Heating, Cooling, Soft Dry and Automatic
Operation.
30 Minutes Time Save Control
• Heating operation only.
Quiet Operation
• To provide quiet operation.
Ionizer Operation
• Generate and discharge negative ion.
•
POWER
(Green) ............. Lights up in operation,
blinks in Automatic
Operation judging and
Hot Start operation.
Operation judging and
Hot Start operation.
•
TIMER
(Orange) ............ Lights up in Timer
Setting.
•
QUIET
(Orange) ............. Lights up in Quiet
Operation.
•
POWERFUL
(Orange) ...... Lights up in Powerful
Operation.
•
ION
(Green) .................. Lights up in Ionizer
Operation.
•
SUPER
ALLERU-BUSTER
ALLERU-BUSTER
(Blue) ... Lights up in operation.
4
CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12DKD CU-A12DKD /