Report No.: TP11100216-ST
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
14.3.1
Transformers and inductors marked with
manufacturer's name and type .............................. :
manufacturer's name and type .............................. :
T501: Transtec
TT093050527D-E
Alt. T501: Huizhou GP Wiring
Technology Ltd.
TD-230-0300+C
TR1:
DW KB1157-11486
P
Transformers and inductors separately approved :
No
N/A
14.3.2
General
14.3.3, 14.3.4.1 and 14.3.5.1
P
Insulation material complies with clause 20.1.4
P
14.3.3
Constructional requirements
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
P
14.3.3.2
Transformers meet the constructional requirements
P
14.3.4
Separation between windings
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation) ............................. :
between hazardous live parts and accessible parts
(double or reinforced insulation) ............................. :
T501: Prim-secondary
distances:
TT093050527D-E: 14 mm
Alt. T501: Prim-sec.
TD-230-0300E+C: 18 mm
TR1: Prim.-sec.: > 10 mm
P
Coil formers and partition walls > 0,4 mm
TR1: Sec. winding is TIW
T501: Thin sheet
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
N/A
14.3.4.3
Separating transformers with at least basic insulation
N/A
14.3.5
Insulation between HAZARDOUS LIVE parts and ACCESSIBLE parts
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
T501: Iron core is floating
Inside the transformer
(toroidal transformer)
TR1: Core not connected to
accessible parts
accessible parts
P
Coil formers and partition walls > 0,4 mm
TR1: Core floating
T501: Thin sheet tape
N/A
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
No such transformer
N/A