Read JBL SUB Brochure online
Page 13 of 36
Report No.: TP11100216-ST
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
12.1.3
Impact hammer test
P
Steel ball test
P
12.1.4
Drop test for portable apparatus where mass
≤
7 kg
N/A
12.1.5
Thermoplastic enclosures stress relief test
P
12.2
Fixing of knobs, push buttons, keys and levers
P
12.3
Remote controls with hazardous live parts
N/A
12.4
Drawers (pull test 50 N, 10 s)
N/A
12.5
Antenna coaxial sockets providing isolation
N/A
12.6
Telescoping or rod antennas construction
N/A
12.6.1
Telescoping or rod antennas securement
N/A
13
Clearances and creepage distances
P
13.1
Clearances in accordance with 13.3
Pollution degree 2
P
Creepage distances in accordance with 13.4
Pollution degree 2 and material
group IIIb
group IIIb
P
13.2
Determination of working voltage
P
13.3
Clearances
P
13.3.1
General
P
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9............. :
with table 8 and, where applicable, table 9............. :
(see appended table)
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
Circuits not conductively
connected to the mains cannot
cause any shock hazard
connected to the mains cannot
cause any shock hazard
N/A
13.3.4
Measurement of transient voltages
N/A
13.4
Creepage distances
P
Creepage distances greater than table 11 minimum
values
values
(see appended table)
P
13.5
Printed boards
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
No such PCB used
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
Click on the first or last page to see other SUB service manuals if exist.