SUB - JBL Audio Brochure (repair manual). Page 17

Read JBL SUB Brochure online

 
Page 16 of 36
    
Report No.: TP11100216-ST 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity  
 
N/A 
14.4 
High voltage components  
N/A 
 
High-voltage components and assemblies: U > 4 kV 
(peak) separately approved  
(see appended table) 
N/A 
 
Component meets category V-1 of IEC 60707  
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission  
 
N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission  
 
N/A 
14.5 
Protective devices  
  
 
Protective devices used within their ratings  
 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened  
  
14.5.1.1 
a) Thermal cut-outs separately approved  
No such components 
N/A 
 
b) Thermal cut-outs tested as part of the submission   
N/A 
14.5.1.2 
a) Thermal links separately approved  
 
 
b) Thermal links tested as part of the submission  
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering  
No such components 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127  
  
14.5.2.2 
Correct marking of fuse-links adjacent to holder  ... : 
T2.5AL/ 250 V 
On standby PCB; 
Fuse T250mA/ 250 V 
14.5.2.3 
Not possible to connect fuses in parallel  ............... : 
  
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool ......... : 
 
14.5.3 
PTC thermistors comply with IEC 60730-1:2007 
No such components 
N/A 
 
PTC devices (15 W) category V-1 or better  
 
N/A 
14.5.4 
Circuit protectors have adequate breaking capacity 
and their position is correctly marked  
No such components 
N/A 
14.6 
Switches  
  
14.6.1 a) 
Separate testing to IEC 61058-1 including: 
- 10 000 operations 
- Normal pollution suitability 
- Make and break speed independent of speed of 
  actuation 
V-0 compliance with annex G, G.1.1  
Mains switch 
Rated 128A 250Vac 
59A (measured) 
Relay K1: 39 A (calculated) 
14.6.1 b) 
Tested in the apparatus: 
  
Page of 46
Display

Click on the first or last page to see other SUB service manuals if exist.