Report No.: TP11100216-ST
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
N/A
High-voltage components and assemblies: U > 4 kV
(peak) separately approved
(peak) separately approved
(see appended table)
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5
Protective devices
Protective devices used within their ratings
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
P
14.5.1.1
a) Thermal cut-outs separately approved
No such components
N/A
b) Thermal cut-outs tested as part of the submission
N/A
14.5.1.2
a) Thermal links separately approved
P
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
No such components
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... :
T2.5AL/ 250 V
On standby PCB;
Fuse T250mA/ 250 V
P
14.5.2.3
Not possible to connect fuses in parallel ............... :
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
P
14.5.3
PTC thermistors comply with IEC 60730-1:2007
No such components
N/A
PTC devices (15 W) category V-1 or better
N/A
14.5.4
Circuit protectors have adequate breaking capacity
and their position is correctly marked
and their position is correctly marked
No such components
N/A
14.6
Switches
14.6.1 a)
Separate testing to IEC 61058-1 including:
- 10 000 operations
- Normal pollution suitability
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
- 10 000 operations
- Normal pollution suitability
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
Mains switch
Rated 128A 250Vac
59A (measured)
Relay K1: 39 A (calculated)
P
14.6.1 b)
Tested in the apparatus:
-