Read JBL SUB Brochure online
Page 10 of 36
Report No.: TP11100216-ST
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
TR1: TIW wire
T501: TT093050527D-E
Thin sheet insulation tape with
a thickness of 0.05 mm.
a thickness of 0.05 mm.
And alt.
T501: TD230-0300E+C
Thin sheet insulation tape with
a thickness of 0.08 mm.
a thickness of 0.08 mm.
P
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
conductors and accessible parts
Min. 0.4 mm
P
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
parts and conductors connected to accessible parts
Min. 0.4 mm
P
8.10
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
See clause 8.9
P
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
P
8.11
Detaching of wires
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
No risk of any wires detached
N/A
Vibration test carried out ........................................ :
No, no need. See above.
N/A
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
N/A
8.14
Adequate fastening of covers (push/pull test 50 N for
10 s)
10 s)
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
P
8.16
Only special supply equipment can be used
Not such apparatus
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
Not used
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
8.19.1
Disconnect device
Mains plug is provided
P
All-pole switch or circuit breaker with >3mm contact
separation
separation
No such devices
N/A
8.19.2
Mains switch ON indication
Power ON, + green LED
N/A
8.20
Switch not fitted in the mains cord
P
8.21
Bridging components comply with clause 14
C15 (Relay shunt)
P
8.22
Non-separable thin sheet material
No such material
N/A
Click on the first or last page to see other SUB service manuals if exist.