SUB - JBL Audio Brochure (repair manual). Page 15

Read JBL SUB Brochure online

 
Page 14 of 36
    
Report No.: TP11100216-ST 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
Temperature cycle test and dielectric strength test  
 
N/A 
 
500V test for transformers, magnetic coupler and 
similar devices, if insulation is relied upon for safety 
 
N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts 
not conductively connected to the mains, clearances 
and creepage distances as in table 12  
 
N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8  
 
N/A 
 
14 
Components 
 
14.1 
Resistors  
No such components 
N/A 
 
a) Resistors between hazardous live parts and 
accessible metal parts  
 
N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts  
 
N/A 
 
Resistors separately approved  .............................. : 
 
N/A 
14.2 
Capacitors and RC units  
 
N/A 
 
Capacitors separately approved  : 
Yes 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 
edition ……: 
Y1: C03 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 
edition ……: 
X2: C06, C15, C19 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2  ..................... : 
No such components 
N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, where 
short-circuit current exceeds 0,2 A: compliance with 
IEC 60384-1, 4.38 category B or better ................. : 
C6, C19 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60384-1, 4.38 
category B or better  ................................................ : 
 
N/A 
 
Shielded by a barrier acc. to 20.1.4/ table 21 or 
metal  ....................................................................... : 
 
N/A 
14.3 
Inductors and windings  
  
  
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4  
  
N/A 
Page of 46