Read JBL ON TIME 200ID (serv.man2) EMC - CB Certificate online
<12014165 001>
Page 19 of 73
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
IEC60065E
ASTABEAB
See sub-clause 8.8.
P
14.12
Surge suppression varistors
P
Comply with IEC 61051-2
Certified sources of varistors are used.
(see appended table)
P
Not connected between mains and accessible
parts except for earthed parts of permanently
connected apparatus
parts except for earthed parts of permanently
connected apparatus
Not connected to accessible parts/output
circuits.
circuits.
P
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
Certified source with suitable
characteristics used.
characteristics used.
P
15
TERMINALS
P
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
couplers and mains socket-outlet meet the
appropriate standard
A mains plug that is part of direct plug-in
equipment provided. Details see table
14.
equipment provided. Details see table
14.
P
15.1.2
Connectors for antenna, earth, audio, video or data:
P
No risk of insertion in mains socket-outlets
Output connector.
P
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
P
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-
outlets
not compatible with household mains socket-
outlets
P
15.2
Provision for protective earthing
N/A
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
reliably connected to earth terminal, within
equipment
Class II appliance.
N/A
Class I supply equipment with non-hazardous live
output voltage: output circuit not connected to earth
output voltage: output circuit not connected to earth
N/A
Protective earth conductors correctly coloured
N/A
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
provided with separate protective earth terminal
near mains input
N/A
Earthing connection of parts removable by hand.
N/A
Protective earth terminal resistant to corrosion
N/A
Earth resistance test: < 0,1 Ω at 25 A ................... :
N/A
Click on the first or last page to see other ON TIME 200ID (serv.man2) service manuals if exist.