IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
IEC60065E 
 
ASTABEAB 
14.3.4.3 
Separating transformers with at least basic 
insulation 
Not such a transformer design. 
N/A 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
See sub-clause 14.3.4.1 above. 
 
Coil formers and partition walls = 0,4 mm 
 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
Not a class I transformer design. 
N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 
N/A 
14.4 
High voltage components 
N/A 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
No component operating at voltage 
exceeding 4kV. 
N/A 
 
Component meets category V-1 of IEC 60707 
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 
N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 
N/A 
14.5 
Protective devices 
 
Protective devices used within their ratings 
See sub-clause 14.5.2.1. 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened 
(see appended table 13.3 and 13.4) 
14.5.1.1 
a) Thermal cut-outs separately approved 
No thermal cut-outs provided. 
N/A 
 
b) Thermal cut-outs tested as part of the 
submission 
 
N/A 
14.5.1.2 
a) Thermal links separately approved 
No thermal link provided. 
N/A 
 
b) Thermal links tested as part of the submission 
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering 
No such components provided. 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127 
Fuse link source complies with IEC 
60127-2. For source details refer to 
appended table 14. 
14.5.2.2 
Correct marking of fuse-links adjacent to holder  ... :  Fuse marked on PCB adjacent to 
component as: F1 T3,15AL250V. 
Page of 91