Read JBL ON TIME 200ID (serv.man2) EMC - CB Certificate online
<12014165 001>
Page 17 of 73
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
IEC60065E
ASTABEAB
14.5.2.3
Not possible to connect fuses in parallel ................ : No such holders provided that would
allow parallel connection.
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool .......... :
replacing fuse-links without the use of a tool .......... :
No fuse link can be replaced without
use a tool.
use a tool.
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
No such components provided.
N/A
PTC-S devices (15 W) category V-1 or better
N/A
14.5.4
Circuit protectors have adequate breaking capacity
and their position is correctly marked
and their position is correctly marked
Fusing resistor is used, detail see page 3
and marked on PCB adjacent to
components as: F1 2,2Ω/1W.
and marked on PCB adjacent to
components as: F1 2,2Ω/1W.
The test under fault condition is carried
out three times.
out three times.
P
14.6
Switches
No switches provided.
N/A
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
V-0 compliance with annex G, G.1.1
and
Peak inrush rating of switch
Measured/calculated inrush…………………………:
N/A
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3,
14.6.4 and V-0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.3,
14.6.4 and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1
N/A
Switch controlling = 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.4 and V-
0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.4 and V-
0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d), l) and m) not
attaining excessive temperatures in use
61058-1 subclause 16.2.2 d), l) and m) not
attaining excessive temperatures in use
N/A
Click on the first or last page to see other ON TIME 200ID (serv.man2) service manuals if exist.