ON TIME 200ID (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 18

Read JBL ON TIME 200ID (serv.man2) EMC - CB Certificate online

 
 
<12014165 001> 
 
 
Page 17 of 73 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
IEC60065E 
 
ASTABEAB 
14.5.2.3 
Not possible to connect fuses in parallel  ................ :  No such holders provided that would 
allow parallel connection. 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool .......... : 
No fuse link can be replaced without 
use a tool. 
14.5.3 
PTC-S thermistors comply with IEC 60730-1 
No such components provided. 
N/A 
 
PTC-S devices (15 W) category V-1 or better 
 
N/A 
14.5.4 
Circuit protectors have adequate breaking capacity 
and their position is correctly marked 
Fusing resistor is used, detail see page 3 
and marked on PCB adjacent to 
components as: F1 2,2Ω/1W. 
The test under fault condition is carried 
out three times. 
14.6 
Switches 
No switches provided. 
N/A 
14.6.1 a) 
Separate testing to IEC 61058 including: 
10 000 operations 
Normal pollution suitability 
Resistance to heat and fire level 3 
V-0 compliance with annex G, G.1.1 
and 
Peak inrush rating of switch 
Measured/calculated inrush…………………………: 
 
N/A 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact voltage 
> 35 V (peak)/24 V dc complying with 14.6.3, 
14.6.4 and V-0 in annex G, G.1.1 
 
N/A 
 
Switch controlling > 0.2A with open contact voltage 
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1 
 
N/A 
 
Switch controlling = 0.2A with open contact voltage 
> 35 V (peak)/24 V dc complying with 14.6.4 and V-
0 in annex G, G.1.1 
 
N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 
61058-1 subclause 13.1 and has making/breaking 
action independent of speed of actuation 
 
N/A 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 
61058-1 subclause 16.2.2 d), l) and m) not 
attaining excessive temperatures in use 
 
N/A 
Page of 91