ON TIME 200ID (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 16

Read JBL ON TIME 200ID (serv.man2) EMC - CB Certificate online

 
 
<12014165 001> 
 
 
Page 15 of 73 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
IEC60065E 
 
ASTABEAB 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition  ... :  The capacitor CX1 conductively 
connected between the lines of the mains 
supply is subclass X2 capacitor approved 
according to IEC 60384-14+A1. 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2 ...................... : 
No such capacitors provided. 
N/A 
14.2.5     a)  Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0,2 A: 
compliance with IEC60384-1, 4.38 category B or 
better  ....................................................................... : 
All sources of the X capacitors are tested 
as category B or better according to sub-
clause 4.38 of IEC 60384-14. 
b) 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 
4.38 category B or better  ........................................ : 
Electrolytic capacitors provided with 
metal can. 
 
Shielded by a barrier per Table 21 .......................... :   
N/A 
14.3 
Inductors and windings 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
 
N/A 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type  ............................... : 
The transformer is marked with type and 
manufacturer information (as code), 
provided as label on the cores. 
 
Transformers and inductors separately approved  . :  Tested with appliance. 
N/A 
14.3.2 
General 
 
14.3.3 
Constructional requirements (complete appended 
tables or include manufacturers constructional 
insulation descriptions) 
See below. 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
(see appended table 13.3 and 13.4) 
14.3.3.2 
Transformers meet the constructional 
requirements 
 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Reinforced or double insulation between 
primary winding/parts and secondary 
winding/parts. Details see appended 
table 13.3 and 13.4. 
 
Coil formers and partition walls = 0,4 mm 
  Partition wall of T1 with 0,5mm 
thickness minimum. 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
Not a class I transformer design. 
N/A 