ON TIME 200ID (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 15

Read JBL ON TIME 200ID (serv.man2) EMC - CB Certificate online

 
 
<12014165 001> 
 
 
Page 14 of 73 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
IEC60065E 
 
ASTABEAB 
13.4 
Creepage distances 
 
 
Creepage distances greater than table 11 minima 
(see appended table) 
13.5 
Printed boards 
No coated PCB used. 
N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
 
N/A 
13.5.2 
Type B coated printed circuit boards complying with 
IEC 60664-3 (basic insulation only) 
 
N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4 
No such parts provided. 
N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 
N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12 
Not such a construction. 
N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
The sources of optocoupler is in 
compliance with the requirements of sub-
clause 8.8, for details refer to appended 
table 14. 
 
 
 
 
14 
COMPONENTS 
14.1 
Resistors 
N/A 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
No such resistors provided. 
N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 
N/A 
 
Resistors separately approved  ............................... :   
N/A 
14.2 
Capacitors and RC units 
 
Capacitors separately approved 
(see appended table) 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition  ... :  The capacitor CY1 connected between 
the hazardous live and secondary circuits 
is subclass Y1 capacitor approved 
according to IEC 60384-14+A1. 
Page of 91