Read JBL ON TIME 200ID (serv.man2) EMC - CB Certificate online
<12014165 001>
Page 14 of 73
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
IEC60065E
ASTABEAB
13.4
Creepage distances
P
Creepage distances greater than table 11 minima
(see appended table)
P
13.5
Printed boards
No coated PCB used.
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
No such parts provided.
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
not conductively connected to the mains:
clearances and creepage distances as in table 12
Not such a construction.
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
The sources of optocoupler is in
compliance with the requirements of sub-
clause 8.8, for details refer to appended
table 14.
compliance with the requirements of sub-
clause 8.8, for details refer to appended
table 14.
P
14
COMPONENTS
P
14.1
Resistors
N/A
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
No such resistors provided.
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N/A
Resistors separately approved ............................... :
N/A
14.2
Capacitors and RC units
P
Capacitors separately approved
(see appended table)
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition ... : The capacitor CY1 connected between
the hazardous live and secondary circuits
is subclass Y1 capacitor approved
according to IEC 60384-14+A1.
is subclass Y1 capacitor approved
according to IEC 60384-14+A1.
P