ON STAGEII (serv.man6) - JBL Audio EMC - CB Certificate (repair manual). Page 7

Read JBL ON STAGEII (serv.man6) EMC - CB Certificate online

Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Janurary 5,2006 
Harman Multimedia  OnStage UD    CE Test Report 
2006 011114 CE AUS/NZ 
 
7 of 72 
 
Test Specifications Continued: 
Power Line Surge 
Immunity 
IEC 61000-4-5 (2001)
 
  
Electromagnetic Compatibility, Power Line Surge 
Immunity 
RF Common Mode 
Immunity 
IEC 61000-4-6 (2004)
 
  
Electromagnetic Compatibility - Basic Immunity Standard - 
Conducted Disturbances Induced By Radio-Frequency 
Fields - Immunity Test 
Power Frequency 
Magnetic Field 
IEC 61000-4-8 (2001)
 
   
Electromagnetic Compatibility, Testing and Measurement 
Techniques for Power Frequency Magnetic Field, 
Immunity Test 
Voltage Dips and Short 
Interruptions Immunity 
IEC 61000-4-11(2004)  
Electromagnetic Compatibility - Testing and Measurement 
Techniques - Voltage Dips, Short Interruptions and Voltage 
Variations Immunity Tests 
 
1.2.  Test Summary 
1.2.1. 
Emissions Test Summary 
 
Specification 
Frequency Range 
Compliance Status 
EN 55022 (1998), A1(2000), 
A2(2003) , Class “B
Conducted Emissions  
0.15 MHz – 30 MHz  
PASS  
EN 55022 (1998), A1(2000), 
A2(2003) , Class “B 
Telecom Conducted Emissions  
0.15 MHz – 30 MHz  
N/A 
EN 55022 (1998), A1(2000), 
A2(2003) , Class “B 
Radiated Emissions  
30 MHz – 1000 MHz  
PASS  
EN 61000-3-2 (2000), 
A1(2001), A2(2005)  
 
Power Line Harmonics 
up to the 40
th
 Harmonic 
Outside of Test 
Requirement 
EN 61000-3-3 (1995), 
A1(2001)  
Power Line Flicker 
less than or equal to
 4% Maximum Relative 
Voltage Change;  Value of D(T) 
less than or equal 
to
 3% for more than 200 Ms 
Outside of Test 
Requirement 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 72
Display