DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Janurary 5,2006 
Harman Multimedia  OnStage UD    CE Test Report 
2006 011114 CE AUS/NZ 
 
6 of 72 
 
1.  ADMINISTRATIVE DATA AND TEST SUMMARY 
1.1.  Administrative Data 
 
CLIENT: 
Harman Multimedia
 
8500 Balboa Blvd.
 
 
818 830-8764
 
 
CONTACT: 
Robert Tang
 
 
DATE (S) OF TEST: 
 January 3, 2005 to January 5, 2005   
 
EQUIPMENT UNDER TEST (EUT): 
Computer Speaker System
 
 
 
Model
 
OnStage UD
 
 
 
Condition Upon Receipt 
Suitable for Test 
 
TEST SPECIFICATION: 
Radio Frequency Emissions and Electromagnetic Immunity 
tests in accordance with requirements of EN 55022 (1998), 
A1(2000), A2(2003)  and EN 55024 (1998), A1(2001), 
A2(2003)  as follows: 
Test Type 
In Accordance with 
Document 
Document Title 
Conducted and 
Radiated Emissions 
EN 55022 (1998), 
A1(2000), A2(2003)  
Class ““B” 
Specifications for Limits and Methods of Measurement 
of Radio Disturbance Characteristics of Information 
Technology Equipment (ITE) 
Power Line Harmonics  
EN 61000-3-2 (2000), 
A1(2001), A2(2005)  
 
Electromagnetic Compatibility, Limits for Harmonic 
Current Emissions, Equipment Input Current 
less than 
or equal to
 16A 
Power Line Flicker  
EN 61000-3-3 (1995), 
A1(2001)  
Electromagnetic Compatibility, Limitation of Voltage 
Fluctuations and Flicker In Low-Voltage Supply 
Systems for Equipment with Rated Current 
less than or 
equal to
 16A 
Electrostatic Discharge 
Immunity 
IEC 61000-4-2 (2001)  
Electromagnetic Compatibility for Industrial Process 
Measurement and Control Equipment Electrostatic 
Discharge Requirements 
Radio Frequency 
Immunity 
IEC 61000-4-3 (2002)
 
 
Electromagnetic Compatibility, Basic Immunity 
Standard, Radiated Radio Frequency Electromagnetic 
Field, Immunity Test 
Electrical Fast 
Transient Burst 
Immunity 
IEC 61000-4-4 (2004)
 
 
Electromagnetic Compatibility for Industrial Process 
Measurement and Control Equipment Electrical Fast 
Transient / Burst Requirements 
Page of 72