ON STAGEII (serv.man18) - JBL Audio EMC - CB Certificate (repair manual). Page 74

Read JBL ON STAGEII (serv.man18) EMC - CB Certificate online

IEC 60950-1 1st. Ed, 2001 
- Page 2 of 5 - 
 
 
 
Order No.  46974 
 
 
2.5 
Where a fuse is used to provide Class 2, 
Limited Power Source (or TNV) current 
limiting, it shall not be operator-accessible 
unless it is not interchangeable.  
No such fuse provided. 
N/A 
2.7.1 
Suitable NEC branch circuit protection is 
required for all standard supply outlets, 
receptacles and medium-base or smaller 
lampholders if the supply branch circuit 
protection is not suitable. Power distribution 
transformers distributing power at 100 V or 
more, and rated 10 kVA or more, require 
transformer overcurrent protection. 
No standard supply outlets, 
receptacles, lampholders or such 
transformers. 
N/A 
3.2 
Wiring methods (terminals, leads etc.) used for 
the connection of the equipment to the mains 
shall be in accordance with the NEC/CEC.  
Class III equipment. 
N/A 
3.2.1 
Power supply cords are required to have 
attachment plugs rated not less than 125 
percent of the rated current of the equipment.  
Class III equipment. 
N/A 
3.2.3 
Permanent connection of equipment to the 
mains supply by a power supply cord is not 
permitted, except for certain equipment, such 
as ATMs.  
Class III equipmen, not 
permanently connected to the 
mains. 
N/A 
3.2.5 
Power supply cords are required to be no 
longer than 4.5m in length. 
Flexible power supply cords are required to be 
compatible with Article 400 of the NEC, and 
Tables 11 and 12 of the CEC.  
Class III equipment. 
N/A 
3.2.9 
Permanently connected equipment is required 
to have a suitable wiring compartment and wire 
bending space.  
Class III equipmen, not 
permanently connected to the 
mains. 
N/A 
3.3 
Wiring terminals and associated spacings for 
field wiring connections shall comply with CSA 
C22.2 No. 0.  
Class III equipment. 
N/A 
3.3.3 
Wire binding screws are not permitted to attach 
conductors larger than 10 AWG (5.3mm
2
).  
Class III equipment. 
N/A 
3.3.4 
Terminals for permanent wiring, including 
protective earthing terminals are required to be 
suitable for U.S./Canadian wire gauge sizes, 
rated 125 percent of the equipment rating, and 
specially marked when specified (1.7.7).  
Class III equipmen, not 
permanently connected to the 
mains. 
N/A 
3.4.2 
Motor control devices are required for cord-
connected equipment with a motor if the motor 
is rated more than 12 A, or if the motor has a 
nominal voltage rating greater than 120 V, or is 
rated more than 1/3hp (locked rotor current 
over 43 A).  
No such motors in the equipment. 
N/A 
3.4.8 
Vertically-mounted disconnect switches and 
circuit breakers are required to have the “on” 
position indicated by the handle in the up 
position.  
No such disconnect switch. 
N/A 