ON STAGE (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 20

Read JBL ON STAGE (serv.man3) EMC - CB Certificate online

 
 
 
APPENDIX 
EN 60950:2000  
- Page 1 of 10 - 
 
 
   
 
Order No.  23171 
 
APPENDIX    EN 60950:2000 
(IEC Publication 60950, 3rd edition, 1999) 
CENELEC Common Modifications, Special National Conditions, National Deviations and Other 
Information  
 
EXPLANATION FOR ABBREVIATIONS  
C = CENELEC Common Modification, S = Special National Condition,  A = National Deviation,  
F = Other Information;  AT = Austria, GB = Great Britain, CH = Switzerland, DE = Germany, DK = Denmark,  
ES = Spain, FI = Finland ,  FR = France, IE = Ireland, N O = Norway, SE = Sweden, ALL = All CENELEC Countries 
P = Pass, F = Fail, = Not applicable;  = No verdict required; placed in the column to the right 
1.2.4.1 S 
(DK) 
In Denmark, certain types of Class I 
appliances (see Sub-clause 3.2.1) may be 
provided with a plug not establishing earthing 
continuity when inserted into Danish socket-
outlets.  
Class III equipment. 
1.5.1 A 
(CH, SE) 
Add the following:  
NOTE: Switches containing mercury such as 
thermostats, relays and level controllers are not 
allowed.  
There are no components containing 
mercury in the equipment. 
1.5.8 S 
(NO) 
In Norway, due to the IT power system used, 
capacitors are required to be rated for the 
applicable phase -to-phase voltage (230V)
 
Class III equipment. 
1.7.2 S 
(NO) 
Class I Pluggable Equipment type A 
intended for connection to other equipment or a 
communication network shall, if safety relies on 
connection to protective earth, require a marking 
stating that the equipment must be connected to 
an earthed mains socket-outlet.  
Applicable text is: 
"Apparatet må kun tilkoples jordet stikkontakt" or  
"Jordet stikkontakt skal benyttes når apparatet 
tilkoples datanett"  
Class III equipment with no protective 
earth provided. 
1.7.2 S 
(SE) 
If the separation between the mains and 
SELV terminal relies upon connection to the 
safety earth, the apparatus shall have a marking 
stating that it must be connected to an earthed 
mains socket-outlet. 
The marking text shall be in Swedish and as 
follows: 
"Apparaten skall anslutas till jordat uttag när den 
ansluts till ett nätverk" or "Apparaten skall 
anslutas till jordat uttag". 
Class III equipment with no protective 
earth provided. 
 
Page of 55