APPENDIX
EN 60950:2000
- Page 1 of 10 -
Order No. 23171
APPENDIX EN 60950:2000
(IEC Publication 60950, 3rd edition, 1999)
CENELEC Common Modifications, Special National Conditions, National Deviations and Other
Information
CENELEC Common Modifications, Special National Conditions, National Deviations and Other
Information
EXPLANATION FOR ABBREVIATIONS
C = CENELEC Common Modification, S = Special National Condition, A = National Deviation,
F = Other Information; AT = Austria, GB = Great Britain, CH = Switzerland, DE = Germany, DK = Denmark,
ES = Spain, FI = Finland , FR = France, IE = Ireland, N O = Norway, SE = Sweden, ALL = All CENELEC Countries
P = Pass, F = Fail, N = Not applicable; — = No verdict required; placed in the column to the right
C = CENELEC Common Modification, S = Special National Condition, A = National Deviation,
F = Other Information; AT = Austria, GB = Great Britain, CH = Switzerland, DE = Germany, DK = Denmark,
ES = Spain, FI = Finland , FR = France, IE = Ireland, N O = Norway, SE = Sweden, ALL = All CENELEC Countries
P = Pass, F = Fail, N = Not applicable; — = No verdict required; placed in the column to the right
1.2.4.1 S
(DK)
In Denmark, certain types of Class I
appliances (see Sub-clause 3.2.1) may be
provided with a plug not establishing earthing
continuity when inserted into Danish socket-
outlets.
provided with a plug not establishing earthing
continuity when inserted into Danish socket-
outlets.
Class III equipment.
N
1.5.1 A
(CH, SE)
Add the following:
NOTE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
thermostats, relays and level controllers are not
allowed.
There are no components containing
mercury in the equipment.
mercury in the equipment.
P
1.5.8 S
(NO)
In Norway, due to the IT power system used,
capacitors are required to be rated for the
applicable phase -to-phase voltage (230V)
applicable phase -to-phase voltage (230V)
Class III equipment.
N
1.7.2 S
(NO)
Class I Pluggable Equipment type A
intended for connection to other equipment or a
communication network shall, if safety relies on
connection to protective earth, require a marking
stating that the equipment must be connected to
an earthed mains socket-outlet.
communication network shall, if safety relies on
connection to protective earth, require a marking
stating that the equipment must be connected to
an earthed mains socket-outlet.
Applicable text is:
"Apparatet må kun tilkoples jordet stikkontakt" or
"Jordet stikkontakt skal benyttes når apparatet
tilkoples datanett"
"Apparatet må kun tilkoples jordet stikkontakt" or
"Jordet stikkontakt skal benyttes når apparatet
tilkoples datanett"
Class III equipment with no protective
earth provided.
earth provided.
N
1.7.2 S
(SE)
If the separation between the mains and
SELV terminal relies upon connection to the
safety earth, the apparatus shall have a marking
stating that it must be connected to an earthed
mains socket-outlet.
The marking text shall be in Swedish and as
follows:
"Apparaten skall anslutas till jordat uttag när den
ansluts till ett nätverk" or "Apparaten skall
anslutas till jordat uttag".
safety earth, the apparatus shall have a marking
stating that it must be connected to an earthed
mains socket-outlet.
The marking text shall be in Swedish and as
follows:
"Apparaten skall anslutas till jordat uttag när den
ansluts till ett nätverk" or "Apparaten skall
anslutas till jordat uttag".
Class III equipment with no protective
earth provided.
earth provided.
N