ON STAGE III IIIP (serv.man7) - JBL Audio EMC - CB Certificate (repair manual). Page 36

Read JBL ON STAGE III IIIP (serv.man7) EMC - CB Certificate online

   
                                   Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E07439      page 36 of 66 
 
 
10. ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST 
10.1.Test Equipments 
Item Equipment  Manufacturer Model No. 
Serial No. Last Cal. 
Cal. Interval
1.  
Burst 
Tester 
HAEFELY 
PEFT-JUNIOR 083762-12 May 11, 07  1 Year 
10.2.Block Diagram of Test Setup 
 
 
 
 
 
 
 
 
 
 
 
 
 
  (EUT: Computer Speaker System) 
 
10.2.1.EFT Test Setup 
 
 
 
 
 
 
10.3.Test Standard 
EN 55024: 1998+A1:2001+A2: 2003 (IEC 61000-4-4:2006) 
(Severity Level 2 at 1kV, Severity Level 2 at 0.5kV) 
10.4.Severity Levels and Performance Criterion 
10.4.1.Severity level 
Open Circuit Output Test Voltage  ±10% 
Level 
On Power Supply 
Lines 
On I/O (Input/Output) 
Signal data and control lines
1. 
0.5 kV 
0.25 kV 
2. 
1 kV 
0.5 kV 
3. 
2 kV 
1 kV 
4. 
4 kV 
2 kV 
X Special 
Special 
10.4.2.Performance criterion : 
AC Mains 
EUT and 
Support system
 
AC Mains
Test 
Generator 
PC  
AC Mains
 
Keyboard 
Mouse 
EUT 
AC Mains 
Monitor
a: Audio Cable 
b: USB Cable 
 : Core 
a
Adaptor
b
Page of 66
Display