ON STAGE III IIIP (serv.man7) - JBL Audio EMC - CB Certificate (repair manual). Page 34

Read JBL ON STAGE III IIIP (serv.man7) EMC - CB Certificate online

   
                                   Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E07439      page 34 of 66 
 
 
9.3. Test  Standard 
EN 55024: 1998+A1:2001+A2: 2003 (IEC 61000-4-3: 2002+A1: 2002) 
(Severity Level: 2 at 3V / m) 
9.4. Severity Levels and Performance Criterion 
9.4.1. Severity level 
Level 
Test Field Strength V/m
1.  
2.  
3.  
10 
X Special 
9.4.2. Performance 
criterion 
: A 
9.5. EUT  Configuration 
The configuration of EUT are listed in Section 3.5. 
9.6. Operating Condition of EUT 
Same as radiated test which is listed in Section 4.6. except the test set up replaced by 
Section 9.2. 
9.7. Test  Procedure 
Testing was performed in a Fully anechoic chamber as recommended by IEC 61000-4-3. 
The EUT was placed on an 80 cm high non-conductive table located in the area of field 
uniformity. The radiating antenna was placed 3m in front of the EUT and Support system, 
and dwell time of the radiated interference was controlled by an automated, 
computer-controlled system. The signal source was stepped through the applicable 
frequency range at a rate no faster than 1%  of the fundamental. The signal was amplitude 
modulated 80%  over the frequency range 80 MHz to 1GHz at a level of 3 V/m. The 
dwell time was set at 3.0 s. Field presence was monitored during testing via a field probe 
placed in close proximity to the EUT. Throughout testing, the EUT was closely monitored 
for signs of susceptibility. The test was performed with the antennae oriented in both a 
horizontal and vertical polarization. 
 
All the scanning conditions are as follows : 
 
Condition of Test 
Remarks 
 ---------------------------------------------- 
---------------------------------- 
1.  Test Fielded Strength 
3 V/m (Severity Level 2) 
2.  Radiated Signal 
80% amplitude modulated with a   
 
1kHz sine wave 
3.  Scanning Frequency 
80 - 1000 MHz 
4.  Sweeping time of radiated 
0.0015 decade/s 
5.  Dwell Time 
3.0 Sec. 
9.8. Test  Results 
PASS. 
The EUT was tested and all the test results are listed in next page. 