ON STAGE III IIIP (serv.man7) - JBL Audio EMC - CB Certificate (repair manual). Page 31

Read JBL ON STAGE III IIIP (serv.man7) EMC - CB Certificate online

   
                                   Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E07439      page 31 of 66 
 
 
8.4. Severity Levels and Performance Criterion 
8.4.1. Severity level 
Level Test 
Voltage 
Contact Discharge (kV)
Test Voltage 
Air Discharge (kV) 
1.  
2.  
3.  
4.  
15 
X Special 
Special 
8.4.2. Performance criterion : B 
8.5. EUT  Configuration 
The configuration of EUT are listed in Section 3.5. 
8.6. Operating Condition of EUT 
Same as radiated test which is listed in Section 4.6. except the test set up replaced by 
Section 8.2. 
8.7. Test  Procedure 
8.7.1. Air 
Discharge: 
The test was applied on non-conductive surfaces of EUT. The round discharge tip 
of the discharge electrode was approached as fast as possible to touch the EUT. 
After each discharge, the discharge electrode was removed from the EUT. The 
generator was    re-triggered for a new single discharge and repeated 20 times for 
each pre-selected test point. This procedure was repeated until all the air discharge 
completed 
8.7.2. Contact Discharge: 
All the procedure was same as Section 8.7.1. except that the generator was 
re-triggered for a new single discharge and repeated 50 times for each pre-selected 
test point. the tip of the discharge electrode was touch the EUT before the 
discharge switch was operated. 
8.8. Test  Results 
PASS. 
 
The EUT was tested and all the test results are listed in next page. 
 
Page of 66