Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E07439 page 31 of 66
8.4. Severity Levels and Performance Criterion
8.4.1. Severity level
Level Test
Voltage
Contact Discharge (kV)
Test Voltage
Air Discharge (kV)
1.
2
2
2.
4
4
3.
6
8
4.
8
15
X Special
Special
8.4.2. Performance criterion : B
8.5. EUT Configuration
The configuration of EUT are listed in Section 3.5.
8.6. Operating Condition of EUT
Same as radiated test which is listed in Section 4.6. except the test set up replaced by
Section 8.2.
Section 8.2.
8.7. Test Procedure
8.7.1. Air
Discharge:
The test was applied on non-conductive surfaces of EUT. The round discharge tip
of the discharge electrode was approached as fast as possible to touch the EUT.
After each discharge, the discharge electrode was removed from the EUT. The
generator was re-triggered for a new single discharge and repeated 20 times for
each pre-selected test point. This procedure was repeated until all the air discharge
completed
After each discharge, the discharge electrode was removed from the EUT. The
generator was re-triggered for a new single discharge and repeated 20 times for
each pre-selected test point. This procedure was repeated until all the air discharge
completed
8.7.2. Contact Discharge:
All the procedure was same as Section 8.7.1. except that the generator was
re-triggered for a new single discharge and repeated 50 times for each pre-selected
test point. the tip of the discharge electrode was touch the EUT before the
discharge switch was operated.
test point. the tip of the discharge electrode was touch the EUT before the
discharge switch was operated.
8.8. Test Results
PASS.
The EUT was tested and all the test results are listed in next page.
The EUT was tested and all the test results are listed in next page.