Read JBL ON STAGE III IIIP (serv.man7) EMC - CB Certificate online
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E07439 page 18 of 66
4. RADIATED EMISSION TEST
4.1. Test Equipments
Item
Equipment
Manufacturer Model No.
Serial No.
Last Cal. Cal. Interval
1. EMC Analyzer
Agilent
E7405A
MY42000131 May 11, 07
1 Year
2.
Test Receiver
Rohde &
Schwarz
ESVS10
834468/011 May 11, 07
1 Year
3. Amplifier
Agilent
8447D 2944A10684
Jul.14,
07 1/2
Year
4. Bilog Antenna
Schaffner
CBL6111C
2768
Feb.22, 07
1 Year
RF Cable
MIYAZAKI
8D-FB
10m Chamber No.1
Feb.07, 07
1/2 Year
6. RF
Cable
MIYAZAKI
8D-FB
10m Chamber No.2
Feb.07, 07
1/2 Year
7. RF
Cable
MIYAZAKI
8D-FB
10m Chamber No.3
Feb.07, 07
1/2 Year
8. RF
Cable
MIYAZAKI
8D-FB
10m Chamber No.4
Feb.07, 07
1/2 Year
9. Coaxial Switch
Anritsu
MP59B
M74389
Feb.07, 07
1/2 Year
4.2. Block Diagram of Test Setup