Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E07439 page 19 of 66
4.2.2. In Anechoic Chamber Test Setup Diagram
4.3. Test Standard
EN55022: 1998+A1:2000+A2: 2003
4.4. Radiated Emission Limit
All emanations from a Class B computing devices or system, including any network of
conductors and apparatus connected thereto, shall not exceed the level of field strengths
specified below:
conductors and apparatus connected thereto, shall not exceed the level of field strengths
specified below:
FREQUENCY
(MHz)
DISTANCE
(Meters)
FIELD STRENGTHS LIMITS
(dB
μV/m)
30 ~ 230
10
30
230 ~ 1000
10
37
Note:
(1) Emission level = Antenna Factor + Cable Loss + Reading
(2) The lower limit shall apply at the transition frequencies.
(3) Distance refers to the distance in meters between the test antenna and the
closed point of any part of the EUT.
4.5. EUT Configuration on Test
The EN55022 Class B regulations test method must be used to find the maximum
emission during Radiated Emission test.
emission during Radiated Emission test.
The configuration of EUT is same as used in Conducted Emission test. Please refer to
Section 3.5.
Section 3.5.
4.6. Operating Condition of EUT
4.6.1. Setup the EUT and the simulators as shown on Section 4.2.
4.6.2. Turn on the power of all equipments.
4.6.3. Let the EUT work in test mode (Data Transmitting) and test it.
ANTENNA TOWER
ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS
GROUND PLANE
10 METERS
TURN TABLE
0.8 METER
EUT and
Support System
Support System