Read JBL ON STAGE III IIIP (serv.man7) EMC - CB Certificate online
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E07439 page 20 of 66
4.7. Test Procedure
The EUT was placed on a non-metallic table, 80 cm above the ground plane inside a
semi-anechoic chamber. An antenna was located 10m from the EUT on an adjustable
mast. A pre-scan was first performed in order to find prominent radiated emissions. For
final emissions measurements at each frequency of interest, the EUT were rotated and the
antenna height was varied between 1m and 4m in order to maximize the emission.
Measurements in both horizontal and vertical polarities were made and the data was
recorded. In order to find the maximum emission, the relative positions of equipments
and all of the interface cables were changed according to EN 55022 Class B on Radiated
Disturbance test.
The bandwidth setting on the test receiver (R&S TEST RECEIVER ESVS10) is 120 kHz.
All the test results and all the scanning waveform are listed in Section 4.8.
mast. A pre-scan was first performed in order to find prominent radiated emissions. For
final emissions measurements at each frequency of interest, the EUT were rotated and the
antenna height was varied between 1m and 4m in order to maximize the emission.
Measurements in both horizontal and vertical polarities were made and the data was
recorded. In order to find the maximum emission, the relative positions of equipments
and all of the interface cables were changed according to EN 55022 Class B on Radiated
Disturbance test.
The bandwidth setting on the test receiver (R&S TEST RECEIVER ESVS10) is 120 kHz.
All the test results and all the scanning waveform are listed in Section 4.8.
4.8. Radiated Disturbance Test Results
PASS. (All emissions not reported below are too low against the prescribed limits.)
The EUT with the following test modes was tested and all the test results are listed in next
pages.
pages.
EUT: Computer Speaker System Model No. : jbl on stage lll
Test Date: Jul.23, 2007 Temperature: 24℃ Humidity: 56%
Test Date: Jul.23, 2007 Temperature: 24℃ Humidity: 56%
The details of test models are as follows:
Reference Test Data
No.
No. Test
Mode
Power Adaptor
Horizontal
Vertical
1.
DSA-20R-12 FEU 120180
#14
#13
2.
Data Transmitting
KSAD1200150W1EU #11 #12
Click on the first or last page to see other ON STAGE III IIIP (serv.man7) service manuals if exist.