IEC 60950-1 (ed.1)
 
 
- Page 6 of 8 - 
 
 
www.nemko.com
 
Report No.   100711 
 
 
TRF No. IECEN60950_1C 
 
 
4.7.201 
4.7.201.5 Testing of printed boards 
The base material of printed boards shall be 
subjected to the needle-flame test of Clause 
4.7.201.3. The flame shall be applied to the edge 
of the board where the heat sink effect is lowest 
when the board is positioned as in normal use. 
The flame shall not be applied to an edge, 
consisting of broken perforations, unless the edge 
is less than 3 mm from a POTENTIAL IGNITION 
SOURCE. 
The test is not carried out if the – 
- Printed board does not carry any POTENTIAL 
IGNITION SOURCE
- Base material of printed boards, on which the 
available apparent power at a connection exceeds 
15 VA operating at a voltage exceeding 50 V and 
equal or less than 400 V (peak) a.c. or d.c. under 
normal operating conditions, is of flammability 
category FV-1 or better according to AS/NZS 
4695.707, or the printed boards are protected by 
an enclosure meeting the flammability category 
FV-0 according to AS/NZS 4695.707, or made of 
metal, having openings only for connecting wires 
which fill the openings completely; or 
- Base material of printed boards, on which the 
available apparent power at a connection exceeds 
15 VA operating at a voltage exceeding 400 V 
(peak) a.c. or d.c. under normal operating 
conditions, and base material of printed boards 
supporting spark gaps which provides protection 
against overvoltages, is of flammability category 
FV-0 according to AS/NZS 4695.707 or the 
printed boards are contained in a metal enclosure, 
having openings only for connecting wires which 
fill the openings completely. 
Compliance shall be determined using the 
smallest thickness of the material. 
NOTE: Available apparent power is the maximum 
apparent power which can be drawn from the supplying 
circuit through a resistive load whose value is chosen to 
maximise the apparent power from more than 2 min 
when the circuit supplied is disconnected.
 
All materials have suitable flame 
class, no testing required. 